5895-01-412-3037 An electronic device which mixes two or more input frequencies which are usually adjustable, combines them linearly in desired proportions to produce a common output signal which is a resultant of the input frequencies. Excludes items having integral oscillators. See also CONVERTER, FREQUENCY, ELECTRONIC and MIXER, CRYSTAL, WAVEGUIDE.20258950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: ZFM1W, ZFM-1W, 5895-01-412-3037, 01-412-3037, 5895014123037, 014123037

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 14 APR 1995 01-412-3037

Drawings & Photos | NSN 5895-01-412-3037


Cross Reference | NSN 5895-01-412-3037

Part Number Cage Code Manufacturer
ZFM-1W 15542 SCIENTIFIC COMPONENTS CORP DBA MINI CIRCUITS LABORATORIES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-412-3037

Technical Data | NSN 5895-01-412-3037

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 0.0 MEGAHERTZ MINIMUM OPERATING CHANNEL AND 750.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
AVERAGE LIFE MEASUREMENT NOT RATED
INCLOSURE TYPE ENCAPSULATED
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 1.250 INCHES NOMINAL
OVERALL HEIGHT 0.750 INCHES NOMINAL
OVERALL WIDTH 1.250 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5895-01-412-3037

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description