NSN 5895-01-365-5613 2663908G001, 01-365-5613, 013655613
Product Details | RADIO FREQUENCY POWER DIVIDER
5895-01-365-5613 An item specifically designed to separate incoming radio frequency power into predetermined proportional values at its output terminals.20358950037Miscellaneous Communication Equipment59850043Antennas, Waveguides, and Related Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: 2663908G001, 5895-01-365-5613, 01-365-5613, 5895013655613, 013655613
Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 08 OCT 1992 | 01-365-5613 | 60411 ( DIVIDER, POWER, RADIO FREQUENCY ) |
Cross Reference | NSN 5895-01-365-5613
Part Number | Cage Code | Manufacturer |
---|---|---|
2663908G001 | 28527 | EXELIS INC. DBA ELECTRONIC SYSTEMS, INTEGRATED |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5895-01-365-5613
Related Products | NSN 5895-01-365-5613
Technical Data | NSN 5895-01-365-5613
Characteristic | Specifications |
---|---|
III END ITEM IDENTIFICATION | CHASSIS,ELECTRICAL-ELECTRONIC EQUIPMENT |
MANUFACTURERS CODE | 28527 |
DESIGN CONTROL REFERENCE | 2663908G001 |
Restrictions/Controls & Freight Information | NSN 5895-01-365-5613
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | J | 100.2 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | ||
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5895-01-365-5613
Category | Code | Description |
---|---|---|
Cognizance Codes | 0R | Interim Supply Support Items for Naval Inventory Control Point, NAVICP PHIL Depot Level Philadelphia Repairables (7R) Naval Inventory Control Point, Philadelphia |
Special Material ID | SM | AN/ALQ-165 Airborne self-protection jammer |
Issue Repair, or Requisition | AR | Repairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved. |
Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
Source of Supply | N32 | Naval Inventory Control Point Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | H | Depot Level Reparable |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |