NSN 5895-00-923-5794 A429622, A42962-2, A429622REVC
Product Details | FREQUENCY MIXER STAGE
5895-00-923-5794 An electronic device which mixes two or more input frequencies which are usually adjustable, combines them linearly in desired proportions to produce a common output signal which is a resultant of the input frequencies. Excludes items having integral oscillators. See also CONVERTER, FREQUENCY, ELECTRONIC and MIXER, CRYSTAL, WAVEGUIDE.20258950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: A429622, A42962-2, A429622REVC, A42962-2REVC, SA9235794, SA9235-794, D438442, D43844-2, 10050-1740, 5895-00-923-5794, 00-923-5794, 5895009235794, 100501740, 009235794
Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 19 APR 1968 | 00-923-5794 | 00334 ( MIXER STAGE, FREQUENCY ) |
Cross Reference | NSN 5895-00-923-5794
Part Number | Cage Code | Manufacturer |
---|---|---|
10050-1740 | 14304 | HARRIS CORPORATION DBA HARRIS RF COMMUNICATION |
A42962-2 | 14304 | HARRIS CORPORATION DBA HARRIS RF COMMUNICATION |
A42962-2 | 42498 | DAR ELECTRONICS INC DBA NATIONAL RADIO CO |
A42962-2REVC | 42498 | DAR ELECTRONICS INC DBA NATIONAL RADIO CO |
D43844-2 | 42498 | DAR ELECTRONICS INC DBA NATIONAL RADIO CO |
SA9235-794 | 56662 | FREQUENCY SELECTIVE NETWORKS INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5895-00-923-5794
Technical Data | NSN 5895-00-923-5794
Characteristic | Specifications |
---|---|
CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
FREQUENCY PER CHANNEL | 15.0 MEGAHERTZ NOMINAL 1ST INPUT CHANNEL 10.0 HERTZ NOMINAL 2ND INPUT CHANNEL 5.0 MEGAHERTZ NOMINAL OUTPUT CHANNEL |
INDIVIDUAL SECTION QUANTITY | 3 |
OPERATING CONTROL METHOD | AUTOMATIC |
AVERAGE LIFE MEASUREMENT | NOT RATED |
OPERATING TEMP RANGE | -40.0 TO 85.0 DEG CELSIUS |
VIBRATION RESISTANCE RANGE IN HERTZ | 5.0 TO 33.0 |
CONNECTION TYPE AND LOCATION | WIRE LEAD TERMINALS BOTTOM |
CONNECTION CONTACT TYPE AND QUANTITY | 6 WIRE LEAD TERMINALS EXTERNAL |
INCLOSURE TYPE | ENCASED |
ENVIRONMENTAL PROTECTION | MOISTURE PROOF AND VIBRATION AND SHOCK RESISTANT AND SALT SPRAY RESISTANT |
INSTALLATION DESIGN | MODULE |
BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
OVERALL LENGTH | 0.578 INCHES MAXIMUM |
OVERALL HEIGHT | 0.562 INCHES MAXIMUM |
OVERALL WIDTH | 0.578 INCHES MAXIMUM |
III UNPACKAGED UNIT WEIGHT | 9.0 GRAMS |
III END ITEM IDENTIFICATION | USED IN ELECT. & COMM EQUIP. |
Restrictions/Controls & Freight Information | NSN 5895-00-923-5794
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 116030 | MACHINES ETC DATA PROCESSING |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5895-00-923-5794
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |