Product Details | SPARK GAP

5840-01-127-4939 An item designed to act as a switching or triggering device by means of a disruptive discharge of electricity (a spark) between the electrodes. The insulation (usually air) between the electrodes is self-restoring after passage of the spark. For spark gaps used as a protective device, see ARRESTER, ELECTRICAL SURGE. For items with additional circuitry which perform complete modulation functions, see MODULATOR, RADAR.20259850043Antennas, Waveguides, and Related Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: 4016347, 401634-7, 5840-01-127-4939, 01-127-4939, 5840011274939, 011274939

Communication, Detection, and Coherent Radiation Equipment | Radar Equipment, Except Airborne

Supply Group (FSG) NSN Assign. NIIN
58 02 MAR 1982 01-127-4939

Cross Reference | NSN 5840-01-127-4939

Part Number Cage Code Manufacturer
401634-7 96214 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5840-01-127-4939

Technical Data | NSN 5840-01-127-4939

Characteristic Specifications
GAP TYPE NONROTARY
ELECTRODE MATERIAL STEEL
ADJUSTABILITY FEATURE NOT INCLUDED
OVERALL DIAMETER 1.250 INCHES NOMINAL
OVERALL LENGTH 4.125 INCHES NOMINAL
MOUNTING CONFIGURATION 1.250 IN. DIA SPRING CLIP MOUNTED
SPECIAL FEATURES FILLED WITH RADIOACTIVE GAS
III END ITEM IDENTIFICATION AN/GPN-24
III FSC APPLICATION DATA RADAR,NON-AIRBORNE,EXCEPT FIRE CONTROL AND GUIDED MISSILE
MANUFACTURERS CODE 96214
DESIGN CONTROL REFERENCE 401634-7

Restrictions/Controls & Freight Information | NSN 5840-01-127-4939

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling D Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.
Special Handling Code D unknonwn
HAZMAT
Type of Cargo N Dangerous materiel in limited quantities (no label required)