NSN 5340-01-127-9600 72150211, 721502-11, 01-127-9600
Product Details | SPACING THREADED STANDOFF
5340-01-127-9600 A standoff that must have a threaded end(s) or be internally threaded its full length. For items having external threads on both ends, see STUD (as modified). For items with an outside contour that is the same for the entire length, are flat on top and bottom, having internal threads its full length, and the length does not exceed twice the width across the flats or outside diameter, see NUT (as modified); use maximum dimensions(s) for compliance.
Part Alternates: 72150211, 721502-11, 5340-01-127-9600, 01-127-9600, 5340011279600, 011279600
Hardware and Abrasives | Hardware, Commercial
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
53 | 11 MAR 1982 | 01-127-9600 | 40280 ( STANDOFF, THREADED, SPACING ) |
Cross Reference | NSN 5340-01-127-9600
Part Number | Cage Code | Manufacturer |
---|---|---|
721502-11 | 05869 | RAYTHEON COMPANY DBA RAYTHEON |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5340-01-127-9600
Related Products | NSN 5340-01-127-9600
Technical Data | NSN 5340-01-127-9600
Characteristic | Specifications |
---|---|
CROSS-SECTIONAL SHAPE | HEXAGON |
DIAMETER | 0.250 INCHES NOMINAL |
STYLE DESIGNATOR | 8 LEFT INTERNAL AND RIGHT INTERNAL THREADS |
LENGTH | 1.120 INCHES NOMINAL |
(NON-CORE DATA) FIRST INTERNAL THREAD LENGTH | 0.138 INCHES NOMINAL |
(NON-CORE DATA) SECOND INTERNAL THREAD LENGTH | 0.138 INCHES NOMINAL |
(NON-CORE DATA) FIRST INTERNAL THREAD CHARACTERISTICS | 0.138 IN. DIA; 32 UNC-2B 0.440 IN. LEADING FROM LEDGE |
(NON-CORE DATA) SECOND INTERNAL THREAD CHARACTERISTICS | 0.138 IN. DIA; 32 UNC-2B 0.440 IN. LEADING FROM EDGE |
(NON-CORE DATA) MATERIAL | STEEL, FED STD 66 |
(NON-CORE DATA) SURFACE TREATMENT | CADMIUM, QQ-P-416, TYPE 2, CLASS 3 |
Restrictions/Controls & Freight Information | NSN 5340-01-127-9600
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |