Product Details | SPACING THREADED STANDOFF

5340-01-106-7737 A standoff that must have a threaded end(s) or be internally threaded its full length. For items having external threads on both ends, see STUD (as modified). For items with an outside contour that is the same for the entire length, are flat on top and bottom, having internal threads its full length, and the length does not exceed twice the width across the flats or outside diameter, see NUT (as modified); use maximum dimensions(s) for compliance.

Part Alternates: 6358743001, 635-8743-001, 5340-01-106-7737, 01-106-7737, 5340011067737, 011067737

Hardware and Abrasives | Hardware, Commercial

Supply Group (FSG) NSN Assign. NIIN
53 24 JAN 1981 01-106-7737

Drawings & Photos | NSN 5340-01-106-7737


Cross Reference | NSN 5340-01-106-7737

Part Number Cage Code Manufacturer
635-8743-001 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5340-01-106-7737

Technical Data | NSN 5340-01-106-7737

Characteristic Specifications
CROSS-SECTIONAL SHAPE HEXAGON
WIDTH ACROSS FLATS 0.250 INCHES NOMINAL
STYLE DESIGNATOR 6 LEFT INTERNAL AND RIGHT EXTERNAL THREAD
LENGTH 0.250 INCHES NOMINAL
(NON-CORE DATA) EXTERNAL THREAD LENGTH 0.310 INCHES MINIMUM
(NON-CORE DATA) FIRST PROJECTION LENGTH 0.560 INCHES NOMINAL
(NON-CORE DATA) FIRST PROJECTION DIAMETER 0.138 INCHES NOMINAL
(NON-CORE DATA) FIRST INTERNAL THREAD LENGTH 0.140 INCHES MINIMUM
(NON-CORE DATA) FIRST INTERNAL THREAD CHARACTERISTICS 6-32 UNC 2B RH
(NON-CORE DATA) EXTERNAL THREAD CHARACTERISTICS 6-32 UNC 2A RH
(NON-CORE DATA) MATERIAL BRASS, QQ-B-626, ALLOY 360
(NON-CORE DATA) SURFACE TREATMENT CHEMICAL FILM,580-0034-000 FSCM 13499
MANUFACTURERS CODE 13499
DESIGN CONTROL REFERENCE 635-8743-001

Restrictions/Controls & Freight Information | NSN 5340-01-106-7737

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information