NSN 5120-01-522-1056 TLUBTS35, TL-UBTS35, X10434A
Product Details | TORQUE SCREWDRIVER
5120-01-522-1056 A manual tool for tightening vairous fasteners to a precise torque value. Consists of a handle and drive to accommodate female square drive sockets, screwdriver bits, and other types of wrenching adapters. Torque value may be manually set and adjusted by user of may be provided as preset for production line use. A signaling device is generally provided to indicate when set torque value is reached. Handle is spun in-line with axis of fastener rotation to apply torque. For items with handles that are swung at right angle to axis of fastener rotation to apply torque, see WRENCH, TORQUE.2025120000065150057Medical and Surgical Instruments, Equipment, and Supplies
Part Alternates: TLUBTS35, TL-UBTS35, X10434A, 5924633, 59246332, 5924633-2, 5120-01-522-1056, 01-522-1056, 5120015221056, 015221056
Hand Tools | Hand Tools, Nonedged, Nonpowered
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
51 | 19 JUL 2004 | 01-522-1056 | 67439 ( SCREWDRIVER, TORQUE ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5120-01-522-1056
Technical Data | NSN 5120-01-522-1056
Characteristic | Specifications |
---|---|
MATERIAL | ALUMINUM OVERALL |
MATERIAL DOCUMENT AND CLASSIFICATION | QQ-A-225/8D FED SPEC ALL MATERIAL RESPONSES OVERALL |
SURFACE TREATMENT | ANODIZE OVERALL |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-A-8625 MIL SPEC ALL TREATMENT RESPONSES OVERALL |
TORQUE CAPACITY | 0.0 INCH-POUNDS MINIMUM AND 30.0 INCH-POUNDS MAXIMUM |
Restrictions/Controls & Freight Information | NSN 5120-01-522-1056
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |