Product Details | CENTRIFUGAL FAN

4140-01-235-5998 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.20216600062Aircraft Air Conditioning, Heating, and Pressurizing Equipment41400043Fans, Air Circulators, and Blower Equipment

Part Alternates: 4EB412AD, 4140-01-235-5998, 01-235-5998, 4140012355998, 012355998

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 03 JUL 1986 01-235-5998

Drawings & Photos | NSN 4140-01-235-5998


Demand History | NSN 4140-01-235-5998

Part Number Request Date QTY Origin
4140-01-235-5998 2013-07-198 1 US
4140-01-235-5998 2013-04-115 1 US

Cross Reference | NSN 4140-01-235-5998

Part Number Cage Code Manufacturer
4EB412AD 03522 ZERO CORP MCLEAN ENGINEERING DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-01-235-5998

Technical Data | NSN 4140-01-235-5998

Characteristic Specifications
STYLE DESIGNATOR 57 FIXED, DUAL, RECTANGULAR OUTLETS
WIDTH 19.000 INCHES NOMINAL
LENGTH 16.344 INCHES NOMINAL
HEIGHT 7.000 INCHES NOMINAL
QUANTITY 4
MATERIAL STEEL CORROSION RESISTING HOUSING
DRIVE TYPE DIRECT
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
PRIME MOVER POWER RATING 325.000 WATTS
OPERATING SPEED AT RATED CAPACITY IN RPM 3200.0
VOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC
PHASE SINGLE
AIR FLOW RATE 600.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE 0.0 INCHES OF WATER
OUTLET LOCATION TOP
DISCHARGE DIRECTION ANGULAR UP AND VERTICAL UP
MANUFACTURERS CODE 03522
DESIGN CONTROL REFERENCE 4EB412AD

Restrictions/Controls & Freight Information | NSN 4140-01-235-5998

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 115030 BLOWERS, OR CENTRIFUGAL FANS
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 72E unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code Q unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable