NSN 4140-01-097-3759 SPARTAN RT 942WF, SPARTANRT942WF, 11454051-3
Product Details | TUBEAXIAL FAN
4140-01-097-3759 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.20316800000259000004140000000
Part Alternates: SPARTAN RT 942WF, SPARTANRT942WF, 11454051-3, 023361, 4140-01-097-3759, 01-097-3759, 4140010973759, 010973759, 114540513
Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | 01-097-3759 | 04244 ( FAN, TUBEAXIAL ) |
Cross Reference | NSN 4140-01-097-3759
Part Number | Cage Code | Manufacturer |
---|---|---|
023361 | 82877 | ROTRON INCORPORATED DBA AMETEK ROTRON MIL AERO WOODSTOCK |
023361000 | 82877 | ROTRON INCORPORATED DBA AMETEK ROTRON MIL AERO WOODSTOCK |
11454051-3 | 18876 | U S ARMY AVIATION AND MISSILE COMMAND |
2129521-6 | 19315 | HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS FORMER BENDIX NAVIGATION AND |
2129521-6 | 55974 | HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS |
A0A3928 | 82877 | ROTRON INCORPORATED DBA AMETEK ROTRON MIL AERO WOODSTOCK |
SPARTAN RT 942WF | 82877 | ROTRON INCORPORATED DBA AMETEK ROTRON MIL AERO WOODSTOCK |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 4140-01-097-3759
Related Products | NSN 4140-01-097-3759
Technical Data | NSN 4140-01-097-3759
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 31 FIXED |
LENGTH | 1.500 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 4.500 INCHES NOMINAL |
MATERIAL | PLASTIC BLADE ALUMINUM HOUSING |
SURFACE TREATMENT | ENAMEL OVERALL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
SPEED ADJUSTMENTS | SINGLE SPEED |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | PARTIALLY INCLOSED |
AMBIENT TEMP AT FULL RATED POWER | 60.0 DEG CELSIUS |
ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
OPERATING SPEED AT RATED CAPACITY IN RPM | 5300.0 |
VOLTAGE IN VOLTS AND CURRENT TYPE | 200.0 AC |
PHASE | THREE |
FREQUENCY IN HERTZ | 400.0 |
AIR FLOW RATE | 175.0 CUBIC FEET PER MINUTE NOMINAL |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
FLOW DIRECTION | OUTWARD |
MOUNTING FACILITY TYPE AND QUANTITY | 3 CLAMP AND 2 RIM |
Restrictions/Controls & Freight Information | NSN 4140-01-097-3759
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Category | Code | Description |
---|---|---|
No Freight Information |