Product Details | VENTILATING FAN

4140-01-006-7314 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.

Part Alternates: XB121, 4140-01-006-7314, 01-006-7314, 4140010067314, 010067314

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 22 JUL 1975 01-006-7314

Drawings & Photos | NSN 4140-01-006-7314


Cross Reference | NSN 4140-01-006-7314

Part Number Cage Code Manufacturer
XB121 97409 EMERSON ELECTRIC CO BUILDER PRODUCTS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-01-006-7314

Technical Data | NSN 4140-01-006-7314

Characteristic Specifications
STYLE DESIGNATOR 45 FIXED
WIDTH 17.250 INCHES NOMINAL
LENGTH 10.109 INCHES NOMINAL
HEIGHT 17.250 INCHES NOMINAL
MATERIAL STEEL OVERALL
SURFACE TREATMENT ENAMEL OVERALL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER NOT RATED
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
PRIME MOVER POWER RATING 0.050 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM 1140.0
VOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC
PHASE SINGLE
FREQUENCY IN HERTZ 60.0
AIR FLOW RATE 1050.0 CUBIC FEET PER MINUTE MAXIMUM
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE 0.0 INCHES OF WATER
FLOW DIRECTION OUTWARD
MOUNTING FACILITY TYPE AND QUANTITY 1 FLANGE
MANUFACTURERS CODE 97409
DESIGN CONTROL REFERENCE XB121

Restrictions/Controls & Freight Information | NSN 4140-01-006-7314

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061920 FANS ELEC NOI IN BARREL/BOX/CRATE
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 752 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable