Product Details | VENTILATING FAN

4140-00-088-3644 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.

Part Alternates: 3151304P1, 315-1304P1, 3151304P1REVB, 315-1304P1REVB, 4140-00-088-3644, 00-088-3644, 4140000883644, 000883644

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 01 JAN 1963 00-088-3644

Drawings & Photos | NSN 4140-00-088-3644


Cross Reference | NSN 4140-00-088-3644

Part Number Cage Code Manufacturer
315-1304P1 2B487 RAYTHEON SERVICE CO LOGISTICS SUPPORT CENTER
315-1304P1REVB 2B487 RAYTHEON SERVICE CO LOGISTICS SUPPORT CENTER

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-00-088-3644

Technical Data | NSN 4140-00-088-3644

Characteristic Specifications
STYLE DESIGNATOR 45 FIXED
WIDTH 4.688 INCHES NOMINAL
LENGTH 3.625 INCHES NOMINAL
HEIGHT 4.688 INCHES NOMINAL
QUANTITY 1
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER -55.0 DEG CELSIUS AND 71.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
OPERATING SPEED AT RATED CAPACITY IN RPM 3100.0
VOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC
PHASE SINGLE
FREQUENCY IN HERTZ 60.0
AIR FLOW RATE 100.000 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE 0.0 INCHES OF WATER
ENVIRONMENTAL PROTECTION DUSTPROOF
FLOW DIRECTION INWARD
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE

Restrictions/Controls & Freight Information | NSN 4140-00-088-3644

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061900 FANS ELEC EXHAUST/VENTILATING
Less than car load rating
Less than truck load rating K 92.5
Water commodity Code 752 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 4140-00-088-3644

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each