NSN 2920-00-774-5946 FMXD1B7U, Y117S1, Y135BS1
Product Details | IGNITION MAGNETO
2920-00-774-5946 An electric generator whose field poles are permanent magnets and which is used to generate electrical energy for the purpose of igniting the combustible mixture in internal combustion engine cylinders. Spark distribution may be accomplished by a distributor portion of the magneto or by a separate item.20229200048Engine Electrical System Components, Nonaircraft29250058Engine Electrical System Components, Aircraft Prime Moving
Part Alternates: FMXD1B7U, Y117S1, Y135BS1, 2920-00-774-5946, 00-774-5946, 2920007745946, 007745946
Engine Accessories | Engine Electrical System Components, Nonaircraft
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
29 | 01 JAN 1960 | 00-774-5946 | 00113 ( MAGNETO, IGNITION ) |
Demand History | NSN 2920-00-774-5946
Part Number | Request Date | QTY | Origin |
---|---|---|---|
Y117S1 | 2015-08-230 | 1 | United States |
Y117S1 | 2007-05-147 | 1 | US |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 2920-00-774-5946
Related Products | NSN 2920-00-774-5946
Technical Data | NSN 2920-00-774-5946
Characteristic | Specifications |
---|---|
IMPULSE QUANTITY PER REVOLUTION | 1 |
IGNITION TYPE FOR WHICH DESIGNED | SINGLE |
SHAFT ROTATION DIRECTION | CLOCKWISE |
DISTRIBUTOR CAP | INCLUDED |
SECONDARY TERMINAL TYPE | PUSH-IN |
BODY MATERIAL | ZINC |
MOUNTING METHOD | FLANGE |
MOUNTING FACILITY | HOLE |
MOUNTING FACILITY QUANTITY | 2 |
MOUNTING HOLE DIAMETER | 0.375 INCHES NOMINAL |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.250 INCHES NOMINAL |
PERFORMANCE TYPE | HIGH TENSION |
ROTATION ELEMENT TYPE | PERMANENT MAGNET ROTOR |
POLE QUANTITY | 2 |
CONTACT SET QUANTITY | 1 |
DRIVE CONNECTION TYPE | IMPULSE COUPLED |
MANUFACTURERS CODE | 82796 |
DESIGN CONTROL REFERENCE | FMXD1B7U |
Restrictions/Controls & Freight Information | NSN 2920-00-774-5946
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 062460 | MAGNETOS/PARTS NOI IN BOXES/CRATES |
Less than car load rating | ||
Less than truck load rating | M | 85.0 |
Water commodity Code | 658 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 2920-00-774-5946
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | J | Ground Forces Support Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
Z EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
Materiel Management Code | C | Construction MaterielDefense Supply Center Columbus (DSCC) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | H | Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
Z EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 3B | Navy-owned stocks of field level repairable DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Reparability | D | Field Level Reparables |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |