NSN 6695-01-515-5803 2485992, 2485-992, 01-515-5803
Product Details | FLUID-HYDRAULIC PRESSURE TRANSDUCER
6695-01-515-5803 An instrument that senses, measures and converts pressure of a hydraulic fluid into electrical signals. The item contains at least one (1) input pressure port and one (1) electrical output connection. The instrument may measure absolute, differential or gage pressure. The sensor may be of the piezoresistive diaphragm, diaphragm with semiconductor strain gage, or foil strain gage construction. Electrical output may be direct or alternating current.
Part Alternates: 2485992, 2485-992, 6695-01-515-5803, 01-515-5803, 6695015155803, 015155803
Instruments and Laboratory Equipment | Combination and Miscellaneous Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 01 DEC 2003 | 01-515-5803 | 52029 ( TRANSDUCER, PRESSURE, FLUID-HYDRAULIC ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6695-01-515-5803
Related Products | NSN 6695-01-515-5803
Technical Data | NSN 6695-01-515-5803
Characteristic | Specifications |
---|---|
CURRENT TYPE | AC |
VOLTAGE RATING | 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
OVERALL LENGTH | 20.000 INCHES NOMINAL |
OVERALL WIDTH | 14.000 INCHES NOMINAL |
OVERALL HEIGHT | 20.000 INCHES NOMINAL |
SPECIAL FEATURES | HYDRAULIC PISTON GAUGE; PRESSURE MEDIUM SPINESSTIC 22 (S22) OR DIOCTYL SEBACATE (DOS) OIL; ACCURACY 100-10000 PSI: 45 PPM; OPERATING TEMPERATURE 18/28 DEGREES C; 15 WATTS |
Restrictions/Controls & Freight Information | NSN 6695-01-515-5803
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |