NSN 6685-01-596-3316 HIH4000001, HIH-4000-001, 01-596-3316
Product Details | RESISTANCE HUMIDITY ELEMENT
6685-01-596-3316 A humidity element consisting primarily of a moisture sensitive chemical whose electrical resistance is proportional to variations in moisture content of the air.
Part Alternates: HIH4000001, HIH-4000-001, 6685-01-596-3316, 01-596-3316, 6685015963316, 015963316
Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 13 MAY 2011 | 01-596-3316 | 03911 ( HUMIDITY ELEMENT, RESISTANCE ) |
Cross Reference | NSN 6685-01-596-3316
Part Number | Cage Code | Manufacturer |
---|---|---|
HIH-4000-001 | 81692 | HONEYWELL INTERNATIONAL INC. DBA HONEYWELL |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6685-01-596-3316
Related Products | NSN 6685-01-596-3316
Technical Data | NSN 6685-01-596-3316
Characteristic | Specifications |
---|---|
MATERIAL | PLASTIC |
MOUNTING METHOD | PIN |
SPECIAL FEATURES | LASER TRIMMED INTERCAHNGEABILITY; LOW POWER DESIGN; HIGH ACCURACY; FAST RESPONSE TIME; STABLE LOW DRIFT PERFORMANCE; CHEMICALLY RESISTANT |
Restrictions/Controls & Freight Information | NSN 6685-01-596-3316
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |