Product Details | DIAL INDICATING PRESSURE GAGE

6685-01-553-5320 An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. It may include a temperature equivalent scale. For items that do not have an internal pressure sensitive element see INDICATOR, PRESSURE.205138600004220000042400027Safety and Rescue Equipment66200018Engine Instruments66850073Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Part Alternates: X32537PW3, X32537P-W3, 6685-01-553-5320, 01-553-5320, 6685015535320, 015535320

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 18 JUL 2007 01-553-5320

Cross Reference | NSN 6685-01-553-5320

Part Number Cage Code Manufacturer
X32537P-W3 01170 BELLOFRAM CORPORATION DBA MARSH-BELLOFRAM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-553-5320

Technical Data | NSN 6685-01-553-5320

Characteristic Specifications
ACTUATION TYPE PRESSURE SENSING ELEMENT
ACTUATING ELEMENT MATERIAL STEEL, STAINLESS
SCALE TYPE DIAL
SCALE NAME PRESSURE
SCALE RANGE 0.0 TO 3000.0 POUNDS PER SQUARE INCH
GRADUATION UNIT 3.0 POUNDS PER SQUARE INCH
SCALE SMALLEST INCREMENT 1.0 POUNDS PER SQUARE INCH
SCALE INSCRIPTION/BACKGROUND COLOR WHITE WITH BLACK MARKINGS
SCALE MARKING PSI AND KPA
POINTER COLOR BLACK
CONNECTOR TYPE VENT PROVIDED
SPECIAL FEATURES STAINLESS STEEL CASE;U-CLAMP MOUNT;1/4NPT CONNECTIONS;HERMETICALLY SEALED;FILL MEDIUM-GLYCERINE
III END ITEM IDENTIFICATION 100MM SEVERE SERVICE GAUGE
III PART NAME ASSIGNED BY CONTROLLING AGENCY GUAGE 0-3000

Restrictions/Controls & Freight Information | NSN 6685-01-553-5320

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information