Product Details | THERMOMETER CALIBRATOR

6685-01-553-1439 An item specifically designed to determine by comparison the accuracy of calibration of thermometers.

Part Alternates: TTI-7 PLUS, TTI7PLUS, 6685-01-553-1439, 01-553-1439, 6685015531439, 015531439

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 09 JUL 2007 01-553-1439

Cross Reference | NSN 6685-01-553-1439

Part Number Cage Code Manufacturer
TTI-7 PLUS 3DNR1 ISOTECH NORTH AMERICA INC DBA SPECMATRIX

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-553-1439

Technical Data | NSN 6685-01-553-1439

Characteristic Specifications
CALIBRATION TYPE DEG CELSIUS
OVERALL LENGTH 315.0 MILLIMETERS NOMINAL
OVERALL WIDTH 219.0 MILLIMETERS NOMINAL
OVERALL HEIGHT 110.3 MILLIMETERS NOMINAL
FURNISHED ITEMS AND QUANTITY PC INTERFACE AND SOFTWARE RS232
SHAPE RECTANGULAR
SPECIAL FEATURES ACCURACY TO 0.01 CELSIUS DEGREE; NEGATIVE 0.001 DEGREE DELSIUS RESOLUTION (PT 100 INPUTS); PRT AND THERMOCOUPLE INPUTS; ELIMINATE UNWANTED THERMAL EMF(S) WITH CURRENT REVERSAL; STORE 4000 MEASUREMENTS; PORTABLE 10 HOURS USE FROM INTERNAL BATTERY; TEMPERATURE RANGE:-200 TO 231 DEGREE CELSIUS DEPENDING ON SENSOR; WORKING TEMPERATURE:0 TO 40 DEGREE CELSIUS RELATIVE HUMIDITY 80 PERCENT MAX NON-CONDENSING; STORAGE TEMPERATURE:-20 TO 50 DEGREE CELSIUS; MAIN SUPPLY:110 VAC +-10 PERCENT (50/60 HZ) 40VA
III UNPACKAGED UNIT WEIGHT 17.600 POUNDS
III PART NAME ASSIGNED BY CONTROLLING AGENCY HIGH-ACCURACY PRT AND TC THERMOMETER

Restrictions/Controls & Freight Information | NSN 6685-01-553-1439

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information