Product Details | DIGITAL HYGROTHERMOMETER

6685-01-261-0297 An instrument for measuring and indicating by digital display relative humidity and temperature of the surrounding atmosphere. Measurements are made by sensors generally mounted in a probe.

Part Alternates: A24803, DMC1S3ATDMPTDMMH13, DM-C1-S3-ATDM-PTDM-MH-13, PA24803, 2001C1S3, 2001-C1-S3, 300C1S3, 300-C1-S3, 6685-01-261-0297, 01-261-0297, 6685012610297, 012610297

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 07 AUG 1987 01-261-0297

Cross Reference | NSN 6685-01-261-0297

Part Number Cage Code Manufacturer
2001-C1-S3 042B6 EDGEONE LLC DBA EDGETECH
300-C1-S3 07926 EG AND G INC MOISTURE AND HUMIDITY DIV
A24803 07926 EG AND G INC MOISTURE AND HUMIDITY DIV
DM-C1-S3-ATDM-PTDM-MH-13 042B6 EDGEONE LLC DBA EDGETECH
PA24803 07926 EG AND G INC MOISTURE AND HUMIDITY DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-261-0297

Technical Data | NSN 6685-01-261-0297

Characteristic Specifications
MEASUREMENT TYPE DIGITAL
VOLTAGE RATING IN VOLTS 115.0 AC NOMINAL AND 230.0 AC NOMINAL
FREQUENCY IN HERTZ 60.0
PHASE SINGLE
DISPLAY TYPE LIGHT EMITTING DIODE
MEASUREMENT RANGE -75.0 TO 130.0 DEG CELSIUS AND 0.1 TO 100.0 PERCENT RELATIVE HUMIDITY
SWITCH TYPE AND QUANTITY 9 PUSH BUTTON
SPECIAL FEATURES USED TO MEASURE TEMPERATURE IN F. AND C. DEG., RELATIVE HUMIDITY AND CALULATES DEW POINT;USES A 3 1/2 DIGIT DISPLAY W ITH A .5 PERCENT ACCURACY;USES A CHILLED AND DRY MIRROR FOR HUMIDITY AND A 3 WIRE PLATINUM RESISTANCE PROBE OF 100 OHMS AT 0 DEG C.;SAMPLE FLOW RATE OF 0.25/2.5 LITERS PER MINUTE AT MAX. PRESSURE OF 300 PSIA;CONTINUOUS BALANCE CONTROL TO ELIMINATE ADJUSTMENTS;BENCH TOP WITH REMOTE ACCESSORIES

Restrictions/Controls & Freight Information | NSN 6685-01-261-0297

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating J 100.2
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6685-01-261-0297

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRNTG:GROUND SUPPORT EQUIPMENT (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1