NSN 6665-01-599-0714 RSS8EOD5, 01-599-0714, 015990714
Product Details | RADIOACTIVE TEST SAMPLE
6665-01-599-0714 A radioactive material used for testing and/or calibrating radioactivity measuring and indicating devices, and/or activating ionsensitive components during test procedures.
Part Alternates: RSS8EOD5, 6665-01-599-0714, 01-599-0714, 6665015990714, 015990714
Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 13 SEP 2011 | 01-599-0714 | 16407 ( RADIOACTIVE TEST SAMPLE ) |
Demand History | NSN 6665-01-599-0714
Part Number | Request Date | QTY | Origin |
---|---|---|---|
6665-01-599-0714 | 2014-02-41 | 9 | DIBBS |
Cross Reference | NSN 6665-01-599-0714
Part Number | Cage Code | Manufacturer |
---|---|---|
RSS8EOD5 | 3A5D0 | SPECTRUM TECHNIQUES LLC DBA SPECTECH |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6665-01-599-0714
Related Products | NSN 6665-01-599-0714
Technical Data | NSN 6665-01-599-0714
Characteristic | Specifications |
---|---|
RADIATION REFERENCE | STANDARD |
NOMINAL ACTIVITY | ACTIVITY=1,HALF-LIFE 10.8 YRS,PEAKS OF INTEREST GAMMA (MEV) 0.081,0.276,0.303 |
VOLUME CALIBRATION IN MILLILITERS | 0.1 |
END ITEM IDENTIFICATION | AN/PDX-1,RADIAC SET |
RADIATION TYPE EMITTED | GAMMA RAYS |
HALF-LIFE IN YEARS | 10.8 |
RADIOACTIVE MATERIAL | BARIUM 133 |
RADIOACTIVE MAGNITUDE RATING | 1.0 MICROCURIES |
CALIBRATED FEATURE | INCLUDED |
Restrictions/Controls & Freight Information | NSN 6665-01-599-0714
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | Y | Information is in the Hazardous Materials Information System (HMIS) |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 6665-01-599-0714
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |