NSN 6665-01-577-2286 07070001, 10010981, 01-577-2286
Product Details | EXPLOSIVE ORDNANCE DETECTOR
6665-01-577-2286 A group of items consisting of x-ray, television, fluoroscopic, image intensifier equipment, and the like, specifically designed for internal and external viewing, for the purpose of detecting and recording the presence and condition of ecplosive devices.
Part Alternates: 07070001, 10010981, 6665-01-577-2286, 01-577-2286, 6665015772286, 015772286
Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 31 AUG 2009 | 01-577-2286 | 62403 ( DETECTOR, EXPLOSIVE ORDNANCE ) |
Demand History | NSN 6665-01-577-2286
Part Number | Request Date | QTY | Origin |
---|---|---|---|
10010981 | 2007-09-253 | 2 | Saudi Arabia |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6665-01-577-2286
Related Products | NSN 6665-01-577-2286
Technical Data | NSN 6665-01-577-2286
Characteristic | Specifications |
---|---|
OVERALL WIDTH | 5.000 INCHES NOMINAL |
FUNCTIONAL DESCRIPTION | SIMULTANEOUS DETECTION OF EXPLOSIVES PARTICULATES WITH VAPORS WITH OR WITHOUT PHYSICAL CONTACT AND IN REAL-TIME |
OVERALL HEIGHT | 7.400 INCHES NOMINAL |
OVERALL LENGTH | 19.400 INCHES NOMINAL |
SPECIAL FEATURES | ION MOBILITY SPECTROMETER (IMS) WITH PHOTONIC NONRADIOACTIVE IONIZATION; 5-30 SEC. USER SELECTABLE ANALYSIS TIME; 15 SECONDS CLEARDOWN TIME; NON-CONTACT VAPOR COLLECTION, PARTICULATE COLLECTION VIA WIPING; 100-240 VAC, 46-63 HZ; 12-15 VDC, 15 A VIA BATTERY; 2 LITHIUM ION RECHARGEABLE BATTERIES; OPERATING TEMPERATURE MINUS 10 TO PLUS 55 DEG. C; OPERATING ALITUDE 4572 M; VISIBLE AND CONFIGURABLE AUDIBLE ALARM; INTEGRATED LCD DISPLAY; AUTOMATIC AND CONTINOUS SELF CALIBRATION |
PART NAME ASSIGNED BY CONTROLLING AGENCY | PORTABLE EXPLOSIVES TRACE DETECTOR |
TYPE/MODEL DESIGNATION | QS-H150 |
Restrictions/Controls & Freight Information | NSN 6665-01-577-2286
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |