Product Details | GAS DETECTOR

6665-01-564-0181 A device specifically designed for the detection and/or evaluation and indication of hazardous gases.

Part Alternates: PIRECLB4A2W, 6665-01-564-0181, 01-564-0181, 6665015640181, 015640181

Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus

Supply Group (FSG) NSN Assign. NIIN
66 02 JUN 2008 01-564-0181

Cross Reference | NSN 6665-01-564-0181

Part Number Cage Code Manufacturer
PIRECLB4A2W 66008 DETECTOR ELECTRONICS CORPORATION DBA DET-TRONICS
PIRECLB4A2W FAUR1 DET-TRONICS FRANCE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6665-01-564-0181

Technical Data | NSN 6665-01-564-0181

Characteristic Specifications
DETECTING ELEMENT TYPE RADIO-PHOTOLUMINESCENT GLASS OR SOLID STATE
DETECTING ELEMENT DETACHABILITY DETACHABLE
VOLTAGE RATING 24.0 VOLTS NOMINAL
THRESHOLD VOLTAGE IN VOLTS 18.0
CASE MATERIAL STEEL, CORROSION RESISTING
CABLE NOT INCLUDED
CONNECTOR INCLUDED
OVERALL LENGTH 9.300 INCHES NOMINAL
OVERALL DIAMETER 4.500 INCHES MINIMUM AND 4.600 INCHES MAXIMUM
OVERALL HEIGHT 5.200 INCHES NOMINAL
SPECIAL FEATURES POINTWATCH ECLIPSE MODEL PIRECL,INFRARED HYDOCARBON GAS DETECTOR;DETECTS MOST FLAMMABLE HYDROCARBON VAPORS,STANDARD GASES INCLUDE METHANE,ETHANE,ETHYLENE,PROPANE,B UTANE AND PROPYLENE;DETECTION OF NON-STANDARD GASES IS CONFIGURABLE USING THE HART COMMUNICATOR;DEFAULT IS METHANE
III END ITEM IDENTIFICATION DETECTION EQUIPMENT
III PART NAME ASSIGNED BY CONTROLLING AGENCY IR HYDROCARBON GAS DETECTOR

Restrictions/Controls & Freight Information | NSN 6665-01-564-0181

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information