Product Details | AUTOMATIC GAS ALARM

6665-01-135-3321 A device which detects the presence of hazardous gases or vapors, toxic explosives, and/or sounds an alarm, and/or lights or flashes lights of distinctive color when the concentration reaches a dangerous level. Excludes ALARM, CHEMICAL AGENT, AUTOMATIC.

Part Alternates: 1641, 720011, 72-0011, 6665-01-135-3321, 01-135-3321, 6665011353321, 011353321

Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus

Supply Group (FSG) NSN Assign. NIIN
66 21 JUL 1982 01-135-3321

Cross Reference | NSN 6665-01-135-3321

Part Number Cage Code Manufacturer
1641 51906 GAS TECH INC
72-0011 51906 GAS TECH INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6665-01-135-3321

Technical Data | NSN 6665-01-135-3321

Characteristic Specifications
MEDIA DETECTED EXPLOSIVE GAS
USAGE DESIGN FIELD
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
DC VOLTAGE RATING 8.0 VOLTS NOMINAL
INTERNAL BATTERY ACCOMMODATION INCLUDED
DIRECT CURRENT RATING IN AMPS 0.5
SPECIFIC USAGE DESIGN SAMPLES ATMOSPHERE FOR PRESENCE OF COMBUSTIBLE GAS,OXYGEN DEFICIENCY,AND HYDROGEN SULFIDE
INDICATOR TYPE FLASHING RED LIGHT
DESIGN TYPE NONTRIPOD MOUNTING

Restrictions/Controls & Freight Information | NSN 6665-01-135-3321

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information