Product Details | RADIACMETER

6665-01-117-2978 An item specifically designed to detect and measure radioactive energy; indicates directly. It may or may not include the function of a radiac computer.

Part Alternates: RO-5B, RO5B, 6665-01-117-2978, 01-117-2978, 6665011172978, 011172978

Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus

Supply Group (FSG) NSN Assign. NIIN
66 12 AUG 1981 01-117-2978

Cross Reference | NSN 6665-01-117-2978

Part Number Cage Code Manufacturer
RO-5B 04596 THERMO EBERLINE LLC DBA THERMO FISHER SCIENTIFIC DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6665-01-117-2978

Technical Data | NSN 6665-01-117-2978

Characteristic Specifications
RADIATION TYPE AND FUNCTION BETA RAYS MEASURES GAMMA RAYS MEASURES X-RAYS MEASURES
RADIATION RANGE PER HOUR 0.1 TO 2000.0 MILLIROENTGENS
COUNT RANGE PER MINUTE NOT RATED
ACCURACY IN PERCENT NOT RATED
INPUT SENSITIVITY VOLTAGE RATING NOT RATED
ENERGY DEPENDENCE RATING 0.010 TO 10.000 MEV
INDICATOR TYPE LIQUID CRYSTAL DISPLAY
DETECTING ELEMENT TYPE IONIZATION CHAMBER
CURRENT TYPE DC
INTERNAL BATTERY ACCOMMODATION INCLUDED
PORTABILITY PORTABLE
CARRYING CASE NOT PROVIDED
CASE MATERIAL PLASTIC
OVERALL LENGTH 9.000 INCHES NOMINAL
OVERALL WIDTH 4.250 INCHES NOMINAL
OVERALL HEIGHT 9.500 INCHES NOMINAL
MOUNTING METHOD PORTABLE
SPECIAL FEATURES BETA WINDOW PROVIDED; WEIGHT INCLUDING BATTERIES IS 3 POUNDS

Restrictions/Controls & Freight Information | NSN 6665-01-117-2978

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information