6665-01-076-3912 An item specifically designed to detect and measure radioactive energy; indicates directly. It may or may not include the function of a radiac computer.

Part Alternates: OA772, OA-772, 6665-01-076-3912, 01-076-3912, 6665010763912, 010763912

Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus

Supply Group (FSG) NSN Assign. NIIN
66 05 MAY 1979 01-076-3912

Cross Reference | NSN 6665-01-076-3912

Part Number Cage Code Manufacturer
OA-772 57774 OVERHOFF TECHNOLOGY CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6665-01-076-3912

Technical Data | NSN 6665-01-076-3912

Characteristic Specifications
RADIATION TYPE AND FUNCTION ALPHA RAYS DETECTS ALPHA RAYS MEASURES
RADIATION RANGE PER HOUR NOT RATED
COUNT RANGE PER MINUTE 0.0 TO 1200.0
ACCURACY IN PERCENT NOT RATED
INPUT SENSITIVITY VOLTAGE RATING NOT RATED
ENERGY DEPENDENCE RATING NOT RATED
INDICATOR TYPE CHRONOMETER
DETECTING ELEMENT TYPE IONIZATION CHAMBER
CURRENT TYPE AC
VOLTAGE IN VOLTS 115.0
PHASE SINGLE
FREQUENCY IN HERTZ 50.0 60.0
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
PORTABILITY PORTABLE
CARRYING CASE NOT PROVIDED
CASE MATERIAL ALUMINUM
OVERALL LENGTH 300.0 MILLIMETERS NOMINAL
OVERALL WIDTH 150.0 MILLIMETERS NOMINAL
OVERALL HEIGHT 150.0 MILLIMETERS NOMINAL
MOUNTING METHOD PORTABLE
III USAGE DESIGN INSTANTANEOUS INDIVIDUAL DETECTION OF AIR IONIZATION BY ALPHA PARTICLES EJECTED DURING A RADIOACTIVE RADON DECAY EVENT

Restrictions/Controls & Freight Information | NSN 6665-01-076-3912

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information