6640-01-573-9895 An item consisting of a reservoir and a temperature control device. It utilizes a liquid media to heat or control samples used in laboratory testing of organic coatings, asphalt and petroleum products. It can also be used to verify the accuracy of temperature sensors or instruments. It may include such components and accessories as water jackets, heaters, cooling coils, circulating pumps, bombs, and racks. Excludes WATER BATH, ELECTRIC and WATER BATH, NONELECTRIC.

Part Alternates: 272103200000, 6640-01-573-9895, 01-573-9895, 6640015739895, 015739895

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 12 MAY 2009 01-573-9895

Cross Reference | NSN 6640-01-573-9895

Part Number Cage Code Manufacturer
272103200000 30234 THERMO NESLAB INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-01-573-9895

Technical Data | NSN 6640-01-573-9895

Characteristic Specifications
CAPACITY RATING 10.0 LITERS NOMINAL
CURRENT TYPE AC
SPECIAL FEATURES COOLING CAPACITY 500 WATTS AT 20 DEG C; 800 WATT HEATER
VOLTAGE RATING 115.0 VOLTS NOMINAL
OVERALL LENGTH 18.875 INCHES
PART NAME ASSIGNED BY CONTROLLING AGENCY DIGITAL ONE REFRIGERATED BATH
FREQUENCY RATING 60.0 HERTZ NOMINAL
INSIDE WIDTH 8.800 INCHES NOMINAL
OVERALL HEIGHT 23.625 INCHES
OVERALL WIDTH 11.375 INCHES
INSIDE DEPTH 6.000 INCHES NOMINAL
INSIDE LENGTH 9.400 INCHES NOMINAL
OPERATING TEMP RANGE -25.0/+150.0 DEG CELSIUS
SHAPE RECTANGULAR

Restrictions/Controls & Freight Information | NSN 6640-01-573-9895

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information