NSN 6640-01-553-1677 GLHP115, GLHP-115, 01-553-1677
Product Details | LABORATORY MIXER
6640-01-553-1677 A mechanical device consisting of a power-driven shaft with a mounted beater that is designed to be used with a mixing bowl or a mixing head that is designed to accommodate laboratory vessels such as tubes and flasks. It is used to prepare liquid emulsions, dissolve low soluble solids, and mix dry materials.
Part Alternates: GLHP115, GLHP-115, 6640-01-553-1677, 01-553-1677, 6640015531677, 015531677
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 10-JUL-07 | 01-553-1677 | 32938 ( MIXER, LABORATORY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-553-1677
Related Products | NSN 6640-01-553-1677
Technical Data | NSN 6640-01-553-1677
Characteristic | Specifications |
---|---|
DESIGN TYPE | OUTPUT SHAFT DRIVE |
OUTPUT SHAFT DRIVE TYPE | DIRECT |
MAXIMUM SPEED RATING IN RPM | 5000.0 AND 30000.0 |
INTEGRAL SPEED CONTROL | INCLUDED |
SPEED CONTROL RANGE IN RPM | 500.0 TO 30000.0 |
ACCESSORY COMPONENTS AND QUANTITY | GEN. LAB HOMOGENIZER (GLH), 10 BY 195MM SAW TOOTH (FINE) SS FEN. PROBE, 20BY195MM SAW TOOTH (FINE) SS GEN PROBE, 35BY195MM FLAT BOTTOM (FINE) SS GEN. PROBE, CROSS ROD, MOTOR STAND ASSEMBLY |
SPECIAL FEATURES | GENERAL LABORATORY HEMOGENIZER PKG (GLHP); DIMENSIONS: 8.5IN HEIGHT, 2.75IN. DIA.; PROCESSING RANGE: 0.03ML-10L |
Restrictions/Controls & Freight Information | NSN 6640-01-553-1677
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |