Product Details | BIOLOGICAL SAFETY CABINET

6640-01-518-2607 An item for control of product quality while reducing exposure to airborne biological agents in hazard research operations.

Part Alternates: 040156, 04-0156, 3620504, 6640NCM040052, 6640-01-518-2607, 01-518-2607, 6640015182607, 015182607

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 05-MAR-04 01-518-2607

Cross Reference | NSN 6640-01-518-2607

Part Number Cage Code Manufacturer
04-0156 89875 DEFENSE LOGISTICS AGENCY DIRECTORATE OF MEDICAL MATERIEL
3620504 94841 LABCONCO CORPORATION
6640NCM040052 64616 DEFENSE MEDICAL STANDARDIZATION BOARD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-01-518-2607

Technical Data | NSN 6640-01-518-2607

Characteristic Specifications
MATERIAL STEEL, STAINLESS
SURFACE TREATMENT ANY ACCEPTABLE
SHAPE RECTANGULAR
CLOSURE METHOD SLIDING DOOR
OVERALL WIDTH 36.000 INCHES NOMINAL
SPECIAL FEATURES 3 FOOT PURIFIER DELTA SERIES CLASS II, TYPE A2 SAFETY CABINET; SAFETY COLOR-CODED AND EPOXY COATED STEEL TOWEL CATCH, SASH POCKET AND PERFORATED EXHAUST FILTER CAP; 10 DEG ANGLED, SLIDING, FULLING-CLOSING 0.25 IN. TEMPERED SA FETY GLASS SASH W/ANTIRACKING MECHANISM; TACTILE POSITION INDICATOR AND 18 IN. MAX LOADING HEIGHT; AIR WAVE ENTRY SYSTEM STAINLESS STEEL AIR FOIL W/RESERVE AIR SECONDARY AIRFLOW SLOTS; CONTAIN-AIR NEGATIVE PRESSURE CHANNEL; EYE-LEVEL, ADA-COMPLIAN AUDIBLE/VISUAL ALARM INDICATOR W/MUTE SWITCH; SURESTART VOLTAGE COMPENSATING SPEED CONTROL W/40 AMP CAPACITY NOMINAL AIRFLOW VELOCITY OF 105 FPM; NOMINAL DOWNFLOW VELOCITY OF 55 FPM; INTRINSICALLY SAFE NEGATIVE AIR PRESSURE DESIGN; 2-99.99% EFFICIENT HEPA FILTERS; THERMALLY PROTECTED PERMANENT SPLIT CAPACITY MOTOR/BLOWER; UNITIZED 16 GAUGE STAINLESS STEEL SUBSTRUCTURE; CREVICE FREE TYPE 304 STAINLESS STEEL INTERIOR AND REMOVEABLE SEAMLESS DISHED WORK SURFACE AND EPOXY COATED EXTERIOR
III END ITEM IDENTIFICATION FOR WORK WITH AGENTS THAT REQUIRE BIOSAEFTY LEVEL 1, 2 OR 3 CONTAINMENT AND ANTINEOPLASTIC DRUG PREPARATION
III SUPPLEMENTARY FEATURES INCLUDES ADJUSTABLE BASE STAND (PART 3730300), CANOPY KIT (PART 3778200), AIR TIGHT DAMPER (PART 37766800), REMOTE BLOWER (PART 3668000), VENTILATING DUCT. LAMINAR FLOW BIOLOGICAL SAFETY CABINET WITH 3 FT TELESCOPING ADJ STAND, 115V; 60HZ, 12 AMPS, FLUORESCENT AND ULTRAVIOLET LIGHTING
III PART NAME ASSIGNED BY CONTROLLING AGENCY HOOD BIOHAZARD 2 HEPA FLTR CLASS II/A/B3 BIOSAFETYLEVEL 1/2/3 115V 3FT

Restrictions/Controls & Freight Information | NSN 6640-01-518-2607

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information