NSN 6640-01-271-4094 110004 W/PROVISIONING, 110004WPROVISIONING, 113004
Product Details | DRY HEAT INCUBATOR
6640-01-271-4094 Item is a heating bath without use of liquid for heating samples. Samples are held in glass or plastic laboratory ware that are supported in a heating block or by beads which distribute the heat.
Part Alternates: 110004 W/PROVISIONING, 110004WPROVISIONING, 113004, 6640-01-271-4094, 01-271-4094, 6640012714094, 012714094
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 24 JAN 1988 | 01-271-4094 | 36778 ( INCUBATOR, DRY HEAT ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-271-4094
Related Products | NSN 6640-01-271-4094
Technical Data | NSN 6640-01-271-4094
Characteristic | Specifications |
---|---|
OPERATING TEMP RANGE IN DEG CELSIUS | 25.0 TO 115.0 |
HEAT SOURCE FOR WHICH DESIGNED | INTEGRAL |
HEATING METHOD | ELECTRICAL |
CURRENT TYPE | AC |
VOLTAGE RATING | 120.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
POWER RATING | 600.0 WATTS NOMINAL |
CIRCULATION METHOD | ANY ACCEPTABLE |
WATER JACKET | NOT PROVIDED |
OVERALL HEIGHT | 10.0 CENTIMETERS NOMINAL |
OVERALL WIDTH | 38.0 CENTIMETERS NOMINAL |
SPECIAL FEATURES | C/O HEATER MTD ON A HEAT DISTRIBUTION PLATE IN THE FLOOR OF THE WATER BATH; W/HEATING BLOCKS,PRODUCES EVEN HEAT DISTRIBUTION TO ALL SIDES OF THE SAMPLE WELLS WITHIN PORM 0.5 DEG C AT 37 DEG C; ON/OFF SWITCH AND A HEAT INDICATOR LAMP |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | INCUBATOR DRY HEAT 25TO115DEG C 120/230V 50/60HZ AC 600WATTS |
Restrictions/Controls & Freight Information | NSN 6640-01-271-4094
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 056760 | ELECTRO-THERAPEUTIC CABINET/PLATE |
Less than car load rating | ||
Less than truck load rating | J | 100.2 |
Water commodity Code | 651 | unknown |
Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6640-01-271-4094
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |