NSN 6640-01-269-5486 SH15040N, SH-1504-0N, 01-269-5486
Product Details | LABORATORY FUME HOOD
6640-01-269-5486 A laboratory furniture device consisting of a housing with an upper extracting compartment, an air by-pass, and which may include a working area. It is designed to exhaust chemical vapors and provide the working area with a flow of clean air. It may contain service outlets for gas, electric, water and air. Design may include such components as cup sinks, cabinets, and work tables. Excludes canopy type hoods.
Part Alternates: SH15040N, SH-1504-0N, 6640-01-269-5486, 01-269-5486, 6640012695486, 012695486
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 18 DEC 1987 | 01-269-5486 | 32709 ( HOOD, FUME, LABORATORY ) |
Cross Reference | NSN 6640-01-269-5486
Part Number | Cage Code | Manufacturer |
---|---|---|
SH-1504-0N | 33420 | KEWAUNEE SCIENTIFIC CORPORATION DBA LABORATORY PRODUCTS GROUP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-269-5486
Related Products | NSN 6640-01-269-5486
Technical Data | NSN 6640-01-269-5486
Characteristic | Specifications |
---|---|
BASIC MATERIAL | STEEL |
HOOD LENGTH | 48.000 INCHES NOMINAL |
HOOD HEIGHT | 68.500 INCHES NOMINAL |
HOOD AIR DUCT QUANTITY | 1 |
III SUPPLEMENTARY FEATURES | ADJUSTABLE UPPER AND LOWER EXHAUST SLOTS; DESIGNED FOR USE IN AIR CONDITIONED LABS; BAFFLES HAVE A FIXED OPENCENTER SLOT; LINING AND BAFFLE IS ASBESTOS-FREE HIGH-DENSITY CALCIUM SILICATE |
MANUFACTURERS CODE | 33420 |
DESIGN CONTROL REFERENCE | SH-1504-0N |
Restrictions/Controls & Freight Information | NSN 6640-01-269-5486
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 014500 | APPARATUS CHEMICAL LABORATORY |
Less than car load rating | P | 77.5 |
Less than truck load rating | F | 150.0 |
Water commodity Code | 732 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |