NSN 6640-01-236-3946 952013, 9520-13, 01-236-3946
Product Details | LABORATORY SYRINGE
6640-01-236-3946 A device consisting of a barrel with a piston or a plunger. May be supplemented with a needle or a delivery orifice on the distal end. May be specially designed. Used to deliver, transfer and/or store gases and fluids in a wide variety of applications, such as gas and liquid chromatography, handling of corrosive gases or liquids and transfer of radioactive and other dangerous gases or liquids. Not intended for injection or use on patients.
Part Alternates: 952013, 9520-13, 6640-01-236-3946, 01-236-3946, 6640012363946, 012363946
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 17 JUL 1986 | 01-236-3946 | 41980 ( SYRINGE, LABORATORY ) |
Cross Reference | NSN 6640-01-236-3946
Part Number | Cage Code | Manufacturer |
---|---|---|
9520-13 | 33110 | ABBOTT LABORATORIES DIV ABBOTT DIAGNOSTICS DIVISION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-236-3946
Related Products | NSN 6640-01-236-3946
Technical Data | NSN 6640-01-236-3946
Characteristic | Specifications |
---|---|
CAPACITY | 250.0 MICROLITERS |
BARREL GLASS TYPE | BOROSILICATE |
SPECIAL FEATURES | SYRINGE,STAINLESS STEEL SHAFT,ALUMINUM KNOB;CTFE PLASTIC SEAL;30 MILLIONTHS OF AN IN. CLEARANCE INSIDE BARREL;GASTIGHT;2 SCALE: ML RANGE 0-.25 IN. SINGLE INCREMENTS,UL RANGE 0-250 IN 25 UL INCREMENTS;ETCHED MARKINGS;METAL LUER LOCK W/CTFE PLASTIC LOWER TAPER;CHROME-PLATED BRASS OUTSIDE,FLUROPOLYMER INSIDE OF SPECIALLY MADE TIP,W/DUAL EXISTS(1 MALE,1 FEMALE),BOTH THREADED;SIDEPORT;FOR USE W/TDX FLUROESENCE POLARIZATION IMMUNOANALYZER |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | SYRINGE LABORATORY BOROSILICATE GLASS BARREL PLUNGER SS SHAFT |
Restrictions/Controls & Freight Information | NSN 6640-01-236-3946
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 056960 | SYRINGES |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 534 | unknown |
Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6640-01-236-3946
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Acquisition Advice Codes | L | LOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | L | LOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |