NSN 6640-01-177-2653 CN 4-155-P, CN4155P, 01-177-2653
Product Details | ELECTRIC WATER BATH
6640-01-177-2653 An item consisting of electric heating element(s) and a liquid reservoir, designed for use in the laboratory for making test(s), such as digestion, evaporation, sterilization and melting by means of heating specimens contained in beakers, flasks, test tubes and the like. Excludes WATER BATH, NONELECTRIC.
Part Alternates: CN 4-155-P, CN4155P, 6640-01-177-2653, 01-177-2653, 6640011772653, 011772653
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 21 APR 1984 | 01-177-2653 | 20327 ( LIQUID BATH, ELECTRIC ) |
Cross Reference | NSN 6640-01-177-2653
Part Number | Cage Code | Manufacturer |
---|---|---|
CN 4-155-P | 64616 | DEFENSE MEDICAL STANDARDIZATION BOARD |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-177-2653
Related Products | NSN 6640-01-177-2653
Technical Data | NSN 6640-01-177-2653
Characteristic | Specifications |
---|---|
RESERVOIR MATERIAL | ALUMINUM |
SHAPE | CYLINDRICAL |
CAPACITY RATING | 2.300 LITERS NOMINAL |
INSIDE DIAMETER | 8.500 INCHES NOMINAL |
INSIDE DEPTH | 2.500 INCHES NOMINAL |
RESERVOIR REMOVABILITY | REMOVABLE |
CONSTANT WATER LEVEL ATTACHMENT | NOT INCLUDED |
LOW WATER CUTOFF | NOT INCLUDED |
INNER SURFACE COLOR | BLACK |
TEST TUBE RACK | NOT INCLUDED |
HEATING ELEMENT QUANTITY | 1 |
HEATING ELEMENT TYPE | ELECTRIC NONIMMERSION |
HEATING ELEMENT CURRENT TYPE | AC |
HEATING ELEMENT VOLTAGE RATING | 120.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL |
HEATING ELEMENT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
HEATING ELEMENT PHASE | SINGLE |
HEATING ELEMENT WATTAGE IN WATTS | 300.0 |
AGITATOR | NOT INCLUDED |
OPERATING TEMP RANGE | 20.0 TO 70.0 DEG CELSIUS |
THERMOREGULATOR | INCLUDED |
ACCURACY RANGE | -0.5 TO 0.5 DEG CELSIUS |
TEMP REGULATING SETTINGS | CONSTANT TEMPERATURE |
COOLING COILS FOR BELOW ROOM TEMP USE | NOT INCLUDED |
INSULATED FEATURE | INCLUDED |
THERMOMETER OPENING | NOT PROVIDED |
PILOT LIGHT | INCLUDED |
ACCESSORY COMPONENTS AND QUANTITY | 1 THERMOMETER W/HOLDER |
SPECIAL FEATURES | BATH INTERIOR BLACK ANODIZED ALUMINUM; STAINLESS STEEL EXTERIOR; 1 POWER CORD; 3 WIRE W/GROUNDING PLUG |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | WATER BATH ELECTRIC ALUMINUM 2.3 L CAP 120/230V 50/60 SGL PHASE |
Restrictions/Controls & Freight Information | NSN 6640-01-177-2653
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 014500 | APPARATUS CHEMICAL LABORATORY |
Less than car load rating | ||
Less than truck load rating | F | 150.0 |
Water commodity Code | 534 | unknown |
Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6640-01-177-2653
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
Accounting Requirements Code | D | Durable item. An item of Army property coded with an ARC of "D" in the AMDF. Durable items do not require property book accountability after issue from the stock record account, but do require hand receipt control when issued to the user. Commercial and fabricated items similar to items coded ?D?in the AMDF are considered durable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | O | If condemned or economically unserviceable, dispose at organizational level. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |