NSN 6640-01-135-1961 S64076, 025478, 025-478
Product Details | LABORATORY OVEN
6640-01-135-1961 An oven used in laboratory procedures to remove moisture from materials which are being tested.
Part Alternates: S64076, 025478, 025-478, 18EM, 31580, 52369320, 52369-320, 7193N20, 7193-N20, 7193N30, 6640-01-135-1961, 01-135-1961, 6640011351961, 011351961
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 18 JUL 1982 | 01-135-1961 | 17096 ( OVEN, LABORATORY ) |
Cross Reference | NSN 6640-01-135-1961
Part Number | Cage Code | Manufacturer |
---|---|---|
025-478 | 15481 | CURTIN MATHESON SCIENTIFIC INC |
18EM | 48619 | PRECISION SCIENTIFIC PETROLEUM INSTRUMENTS CO |
31580 | 48619 | PRECISION SCIENTIFIC PETROLEUM INSTRUMENTS CO |
52369-320 | 08455 | UNIVAR CORP VAN WATERS AND ROGERS INC |
52369-320 | 79011 | VWR INTERNATIONAL INC DBA VWR SCIENTIFIC |
7193-N20 | 59728 | THOMAS, ARTHUR H CO (INC) |
7193N30 | 59728 | THOMAS, ARTHUR H CO (INC) |
S64076 | 64484 | SARGENT-WELCH SCIENTIFIC CO |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-135-1961
Related Products | NSN 6640-01-135-1961
Technical Data | NSN 6640-01-135-1961
Characteristic | Specifications |
---|---|
OPERATING TEMP RANGE IN DEG CELSIUS | 0.0 TO 240.0 |
HEAT SOURCE FOR WHICH DESIGNED | INTEGRAL |
HEATING METHOD | ELECTRICAL |
CURRENT TYPE | AC |
VOLTAGE RATING | 120.0 VOLTS NOMINAL |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
PHASE | SINGLE |
POWER RATING | 1450.0 WATTS NOMINAL |
COOLING COILS FOR BELOW ROOM TEMP USE | NOT INCLUDED |
CIRCULATION METHOD | GRAVITY |
WATER JACKET | NOT PROVIDED |
OVERALL HEIGHT | 32.000 INCHES NOMINAL |
OVERALL WIDTH | 23.000 INCHES NOMINAL |
OVERALL DEPTH | 19.000 INCHES NOMINAL |
INSIDE HEIGHT | 19.000 INCHES NOMINAL |
INSIDE WIDTH | 18.000 INCHES NOMINAL |
INSIDE DEPTH | 14.000 INCHES NOMINAL |
INSULATED CABINET | NOT PROVIDED |
OUTER DOOR QUANTITY | 1 |
OUTER DOOR INSULATION FEATURE | NOT INCLUDED |
SHELF QUANTITY | 2 |
SHELF ADJUSTABILITY | NOT ADJUSTABLE |
VACUUM CHAMBER | NOT INCLUDED |
CONTROL TYPE | THERMOSTAT |
SPECIAL FEATURES | ADJUSTABLE AIR EXHAUST; CONTINUOUSLY VARIABLE DIAL CONTROL |
Restrictions/Controls & Freight Information | NSN 6640-01-135-1961
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 014500 | APPARATUS CHEMICAL LABORATORY |
Less than car load rating | P | 77.5 |
Less than truck load rating | F | 150.0 |
Water commodity Code | 732 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6640-01-135-1961
Category | Code | Description |
---|---|---|
Fund Code | LP | Items initially authorized for local purchase. |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | U | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |