NSN 6640-01-106-0909 13874206, 13-874-206, 01-106-0909
Product Details | ELECTRIC WATER BATH
6640-01-106-0909 An item consisting of electric heating element(s) and a liquid reservoir, designed for use in the laboratory for making test(s), such as digestion, evaporation, sterilization and melting by means of heating specimens contained in beakers, flasks, test tubes and the like. Excludes WATER BATH, NONELECTRIC.
Part Alternates: 13874206, 13-874-206, 6640-01-106-0909, 01-106-0909, 6640011060909, 011060909
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 11 JAN 1981 | 01-106-0909 | 20327 ( LIQUID BATH, ELECTRIC ) |
Cross Reference | NSN 6640-01-106-0909
Part Number | Cage Code | Manufacturer |
---|---|---|
13-874-206 | 22527 | FISHER SCIENTIFIC COMPANY L.L.C. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-106-0909
Related Products | NSN 6640-01-106-0909
Technical Data | NSN 6640-01-106-0909
Characteristic | Specifications |
---|---|
RESERVOIR MATERIAL | STEEL, STAINLESS |
SHAPE | RECTANGULAR |
CAPACITY RATING | 13.0 LITERS NOMINAL |
TEST TUBE RACK | NOT INCLUDED |
HEATING ELEMENT QUANTITY | 1 |
HEATING ELEMENT TYPE | ELECTRIC NONIMMERSION |
HEATING ELEMENT CURRENT TYPE | AC |
HEATING ELEMENT VOLTAGE RATING | 115.0 VOLTS NOMINAL |
HEATING ELEMENT FREQUENCY RATING | 60.0 HERTZ NOMINAL |
HEATING ELEMENT WATTAGE IN WATTS | 1000.0 |
AGITATOR | NOT INCLUDED |
OPERATING TEMP RANGE | -30.0 TO 150.0 DEG CELSIUS |
THERMOREGULATOR | INCLUDED |
ACCURACY RANGE | -0.02 TO 0.02 DEG CELSIUS |
COOLING COILS FOR BELOW ROOM TEMP USE | INCLUDED |
THERMOMETER OPENING | PROVIDED |
OPENING QUANTITY | 1 |
PILOT LIGHT | NOT INCLUDED |
Restrictions/Controls & Freight Information | NSN 6640-01-106-0909
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |