Product Details | LABORATORY FUME HOOD

6640-01-103-2137 A laboratory furniture device consisting of a housing with an upper extracting compartment, an air by-pass, and which may include a working area. It is designed to exhaust chemical vapors and provide the working area with a flow of clean air. It may contain service outlets for gas, electric, water and air. Design may include such components as cup sinks, cabinets, and work tables. Excludes canopy type hoods.

Part Alternates: S4089227G, S40892-27G, S4089227H, S40892-27H, 16311, 16-311, 244321, 244-321, 30155221, 30155-221, 70, 7019005, 70190-05, 72800, 7280000, 6640-01-103-2137, 01-103-2137, 6640011032137, 011032137

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 10 NOV 1980 01-103-2137

Cross Reference | NSN 6640-01-103-2137

Part Number Cage Code Manufacturer
16-311 22527 FISHER SCIENTIFIC COMPANY L.L.C.
244-321 15481 CURTIN MATHESON SCIENTIFIC INC
30155-221 79011 VWR INTERNATIONAL INC DBA VWR SCIENTIFIC
70 94841 LABCONCO CORPORATION
70190-05 94841 LABCONCO CORPORATION
72800 94841 LABCONCO CORPORATION
7280000 94841 LABCONCO CORPORATION
S40892-27G 64484 SARGENT-WELCH SCIENTIFIC CO
S40892-27H 64484 SARGENT-WELCH SCIENTIFIC CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-01-103-2137

Technical Data | NSN 6640-01-103-2137

Characteristic Specifications
BASIC MATERIAL FIBERGLASS
HOOD LENGTH 70.000 INCHES NOMINAL
HOOD HEIGHT 60.000 INCHES NOMINAL
HEATING/AIR CIRCULATING UNIT CONTROL NAME AND QUANTITY SWITCH,BLOWER 1
CURRENT TYPE AC
VOLTAGE IN VOLTS 115.0 OR 230.0
ACCESSORY COMPONENTS AND QUANTITY FLUORESCENT LIGHT 1; COUNTERBALANCED SASH 1; AUTOMATIC AIR BY-PASS 1
SINK QUANTITY 1

Restrictions/Controls & Freight Information | NSN 6640-01-103-2137

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 014500 APPARATUS CHEMICAL LABORATORY
Less than car load rating J 100.2
Less than truck load rating F 150.0
Water commodity Code 72D unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6640-01-103-2137

Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each