Product Details | LABORATORY OVEN

6640-01-052-8326 An oven used in laboratory procedures to remove moisture from materials which are being tested.

Part Alternates: SW17TA, SW-17TA, G01305A, 6640-01-052-8326, 01-052-8326, 6640010528326, 010528326

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 20 DEC 1977 01-052-8326

Cross Reference | NSN 6640-01-052-8326

Part Number Cage Code Manufacturer
G01305A 89715 SPX CORPORATION
SW-17TA 89715 SPX CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-01-052-8326

Technical Data | NSN 6640-01-052-8326

Characteristic Specifications
OPERATING TEMP RANGE IN DEG CELSIUS 40.0 TO 200.0
HEAT SOURCE FOR WHICH DESIGNED INTEGRAL
HEATING METHOD ELECTRICAL
CURRENT TYPE AC
VOLTAGE RATING 120.0 VOLTS NOMINAL
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
PHASE SINGLE
POWER RATING 1600.0 VOLT-AMPERE NOMINAL
CIRCULATION METHOD GRAVITY
WATER JACKET NOT PROVIDED
OVERALL HEIGHT 23.000 INCHES NOMINAL
OVERALL WIDTH 18.000 INCHES NOMINAL
OVERALL DEPTH 14.000 INCHES NOMINAL
INSIDE HEIGHT 16.000 INCHES NOMINAL
INSIDE WIDTH 16.500 INCHES NOMINAL
INSIDE DEPTH 11.500 INCHES NOMINAL
INSULATED CABINET NOT PROVIDED
CABINET OUTER WALL MATERIAL ASBESTOS AND STEEL
OUTER DOOR QUANTITY 1
OUTER DOOR MATERIAL STEEL
OUTER DOOR INSULATION FEATURE NOT INCLUDED
SHELF QUANTITY 2
SHELF ADJUSTABILITY ADJUSTABLE
SHELF MATERIAL WIRE, STEEL
MATERIAL CHARACTERISTIC GRID
VACUUM CHAMBER NOT INCLUDED
CONTROL TYPE ON-OFF SWITCH AND PILOT LIGHT AND TEMPERATURE CONTROL DIAL AND THERMOMETER AND THERMOSTAT

Restrictions/Controls & Freight Information | NSN 6640-01-052-8326

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 056680 DENTAL/MEDICAL/SURG INST R MACHINE
Less than car load rating
Less than truck load rating F 150.0
Water commodity Code 653 unknown
Originating Activity Code 51 Environmental Protection Agency
Washington, DC 20406
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity M Medical supplies, equipment, samples records, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6640-01-052-8326

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each