NSN 6640-01-051-6646 27 62 520-2, 27625202, K2
Product Details | ELECTRIC WATER BATH
6640-01-051-6646 An item consisting of electric heating element(s) and a liquid reservoir, designed for use in the laboratory for making test(s), such as digestion, evaporation, sterilization and melting by means of heating specimens contained in beakers, flasks, test tubes and the like. Excludes WATER BATH, NONELECTRIC.
Part Alternates: 27 62 520-2, 27625202, K2, K-2, 6640-01-051-6646, 01-051-6646, 6640010516646, 010516646
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 03 DEC 1977 | 01-051-6646 | 20327 ( LIQUID BATH, ELECTRIC ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-051-6646
Related Products | NSN 6640-01-051-6646
Technical Data | NSN 6640-01-051-6646
Characteristic | Specifications |
---|---|
RESERVOIR MATERIAL | STEEL, STAINLESS |
SHAPE | RECTANGULAR |
CAPACITY RATING | 3.0 LITERS NOMINAL |
INSIDE DEPTH | 160.0 MILLIMETERS NOMINAL |
RESERVOIR REMOVABILITY | NONREMOVABLE |
TEST TUBE RACK | NOT INCLUDED |
HEATING ELEMENT QUANTITY | 1 |
HEATING ELEMENT TYPE | ELECTRIC IMMERSION |
HEATING ELEMENT CURRENT TYPE | AC |
HEATING ELEMENT VOLTAGE RATING | 115.0 VOLTS NOMINAL |
HEATING ELEMENT FREQUENCY RATING | 60.0 HERTZ NOMINAL |
HEATING ELEMENT PHASE | SINGLE |
HEATING ELEMENT WATTAGE IN WATTS | 900.0 |
AGITATOR | NOT INCLUDED |
OPERATING TEMP RANGE | 40.0 TO 150.0 DEG CELSIUS |
THERMOREGULATOR | INCLUDED |
ACCURACY RANGE | -0.01 TO 0.01 DEG CELSIUS |
COOLING COILS FOR BELOW ROOM TEMP USE | INCLUDED |
ACCESSORY COMPONENTS AND QUANTITY | THERMOMETER 1 |
SPECIAL FEATURES | THERMOREGULATOR TEMP RANGE M5 TO 105 DEG C,MAX PUMP HEAD 10 FT.,PRESSURE PUMP |
Restrictions/Controls & Freight Information | NSN 6640-01-051-6646
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |