NSN 6640-01-020-8753 2292, 01-020-8753, 010208753
Product Details | LABORATORY CENTRIFUGE
6640-01-020-8753 A mechanical device using centrifugal force to separate liquids from solids, which might normally be held by them in suspension, or a liquid of one density from that of another.
Part Alternates: 2292, 6640-01-020-8753, 01-020-8753, 6640010208753, 010208753
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 07 MAY 1976 | 01-020-8753 | 17093 ( CENTRIFUGE, LABORATORY ) |
Cross Reference | NSN 6640-01-020-8753
Part Number | Cage Code | Manufacturer |
---|---|---|
2292 | 30988 | THERMO ELECTRON CORPORATION DBA IEC CENTRIFUGE DIV LABORATORY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-01-020-8753
Related Products | NSN 6640-01-020-8753
Technical Data | NSN 6640-01-020-8753
Characteristic | Specifications |
---|---|
SEPARATION UNIT TYPE | BOWL |
BOWL CAPACITY | 4000.0 MILLILITERS |
MAXIMUM SPEED RATING IN RPM | 6000.0 |
OPERATION METHOD | ELECTRIC |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 208.0 230.0 |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | SINGLE |
GUARD BOWL | INCLUDED |
INSIDE DIAMETER | 21.000 INCHES NOMINAL |
OVERALL WIDTH | 29.000 INCHES NOMINAL |
OVERALL DEPTH | 24.000 INCHES NOMINAL |
OVERALL HEIGHT | 35.000 INCHES NOMINAL |
FURNISHED CONTROLS | TACHOMETER,REFRIGERATION CONTROL,FEEDBACK SPEED CONTROL,TIMER,ON-OFF SWITCH,COAST/BRAKE SWITCH,PUSH BUTTON START SWITCH,TIMER SWITCH |
SPECIAL FEATURES | 4 CASTERS,PILOT LIGHT,FUSE; COOLANT R-12,1/3 HP COMPRESSOR,TEMP RANGE 0-20 DEG C; TIMER RANGE 2-120 MIN.;TACHOMETER RANGE 0 TO 7000 RPM; MAX. GRAVITY 5610 X G; CENTRIFUGE MOTOR .75 HP; STEEL CABINET,BAKED ENAMEL FINISH |
III UNPACKAGED UNIT WEIGHT | 200.000 KILOGRAMS |
Restrictions/Controls & Freight Information | NSN 6640-01-020-8753
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |