6640-00-566-7920 An item consisting of electric heating element(s) and a liquid reservoir, designed for use in the laboratory for making test(s), such as digestion, evaporation, sterilization and melting by means of heating specimens contained in beakers, flasks, test tubes and the like. Excludes WATER BATH, NONELECTRIC.

Part Alternates: 2095, 6640-00-566-7920, 00-566-7920, 6640005667920, 005667920

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 24 NOV 1974 00-566-7920

Cross Reference | NSN 6640-00-566-7920

Part Number Cage Code Manufacturer
2095 04567 MALLINCKRODT INC FORMA SCIENTIFIC DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-00-566-7920

Technical Data | NSN 6640-00-566-7920

Characteristic Specifications
RESERVOIR MATERIAL STEEL, STAINLESS
SHAPE RECTANGULAR
INSIDE LENGTH 12.000 INCHES NOMINAL
INSIDE WIDTH 10.000 INCHES NOMINAL
INSIDE DEPTH 13.000 INCHES NOMINAL
RESERVOIR REMOVABILITY NONREMOVABLE
CONSTANT WATER LEVEL ATTACHMENT INCLUDED
LOW WATER CUTOFF NOT INCLUDED
INNER SURFACE COLOR ANY ACCEPTABLE
COVER QUANTITY 1
COVER TYPE ANY ACCEPTABLE
TEST TUBE RACK NOT INCLUDED
HEATING ELEMENT QUANTITY 1
HEATING ELEMENT TYPE ELECTRIC IMMERSION
HEATING ELEMENT CURRENT TYPE AC
HEATING ELEMENT VOLTAGE RATING 115.0 VOLTS NOMINAL
HEATING ELEMENT FREQUENCY RATING 60.0 HERTZ NOMINAL
HEATING ELEMENT PHASE SINGLE
HEATING ELEMENT WATTAGE IN WATTS 1200.0
AGITATOR NOT INCLUDED
OPERATING TEMP RANGE -20.0 TO 70.0 DEG CELSIUS
THERMOREGULATOR INCLUDED
COOLING COILS FOR BELOW ROOM TEMP USE INCLUDED
MOUNTING TYPE ANY ACCEPTABLE
INSULATED FEATURE INCLUDED
THERMOMETER OPENING NOT PROVIDED
PILOT LIGHT INCLUDED
SPECIAL FEATURES SOLID STATE ELECTRONIC CONTROL SYSTEM,PUMP MOTOR CIRCULATOR
MANUFACTURERS CODE 04567
DESIGN CONTROL REFERENCE 2095

Restrictions/Controls & Freight Information | NSN 6640-00-566-7920

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information