Product Details | ELECTRIC WATER BATH

6640-00-524-6368 An item consisting of electric heating element(s) and a liquid reservoir, designed for use in the laboratory for making test(s), such as digestion, evaporation, sterilization and melting by means of heating specimens contained in beakers, flasks, test tubes and the like. Excludes WATER BATH, NONELECTRIC.

Part Alternates: MW1120A1, 6640-00-524-6368, 00-524-6368, 6640005246368, 005246368

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 23 AUG 1974 00-524-6368

Cross Reference | NSN 6640-00-524-6368

Part Number Cage Code Manufacturer
MW1120A1 89715 SPX CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-00-524-6368

Technical Data | NSN 6640-00-524-6368

Characteristic Specifications
RESERVOIR MATERIAL STEEL, STAINLESS
SHAPE RECTANGULAR
INSIDE LENGTH 18.000 INCHES NOMINAL
INSIDE WIDTH 12.000 INCHES NOMINAL
INSIDE DEPTH 7.500 INCHES NOMINAL
RESERVOIR REMOVABILITY REMOVABLE
CONSTANT WATER LEVEL ATTACHMENT NOT INCLUDED
LOW WATER CUTOFF NOT INCLUDED
TEST TUBE RACK NOT INCLUDED
HEATING ELEMENT QUANTITY 1
HEATING ELEMENT TYPE ELECTRIC IMMERSION
HEATING ELEMENT CURRENT TYPE AC
HEATING ELEMENT VOLTAGE RATING 120.0 VOLTS NOMINAL
HEATING ELEMENT FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
HEATING ELEMENT PHASE SINGLE
HEATING ELEMENT WATTAGE IN WATTS 1600.0
AGITATOR INCLUDED
CURRENT TYPE DC
VOLTAGE RATING ANY ACCEPTABLE
OPERATING TEMP RANGE -10.0 TO 110.0 DEG CELSIUS
THERMOREGULATOR INCLUDED
ACCURACY RANGE -0.2 TO 0.2 DEG CELSIUS
TEMP REGULATING SETTINGS ALL TEMPERATURES WITH TWO MOST USED SELECTED AUTOMATICALLY
COOLING COILS FOR BELOW ROOM TEMP USE NOT INCLUDED
INSULATED FEATURE INCLUDED
THERMOMETER OPENING NOT PROVIDED
PILOT LIGHT INCLUDED
SPECIAL FEATURES WITH SOLID STATE DC POWER SUPPLY ACTUATED ELECTROMAGNET TYPE AGITATOR

Restrictions/Controls & Freight Information | NSN 6640-00-524-6368

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information