NSN 6640-00-299-8690 MS360782, MS36078-2, NNNG00475
Product Details | GLASS TUBING
6640-00-299-8690 A tubular item of glass having a uniform cross section throughout its entire length. It may have reference and/or indicator markings and is generally used where the conveying, containing, or visual inspection of liquids and/or gasses are required, such as laboratories. Excludes INSULATOR (1), WASHER; and WASHER (as modified).20266400033Laboratory Equipment and Supplies93400026Glass Fabricated Materials
Part Alternates: MS360782, MS36078-2, NNNG00475, 6640-00-299-8690, 00-299-8690, 6640002998690, 002998690
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 01 JAN 1963 | 00-299-8690 | 04508 ( TUBING, GLASS ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-00-299-8690
Related Products | NSN 6640-00-299-8690
Technical Data | NSN 6640-00-299-8690
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 19 TUBING |
WALL THICKNESS | 2.62 MILLIMETERS MINIMUM AND 2.87 MILLIMETERS MAXIMUM |
OVERALL LENGTH | 48.000 INCHES NOMINAL |
BORE DIAMETER | 0.75 MILLIMETERS MINIMUM AND 1.25 MILLIMETERS MAXIMUM |
OVERALL DIAMETER | 6.0 MILLIMETERS MINIMUM AND 7.0 MILLIMETERS MAXIMUM |
MATERIAL | GLASS |
MATERIAL DOCUMENT AND CLASSIFICATION | DD-G-541,TYPE 1,CLASS A FED SPEC SINGLE MATERIAL RESPONSE |
MATERIAL TRANSPARENCY | CLEAR |
TEMP AT MAXIMUM OPERATING PRESSURE | NOT RATED |
SPECIAL FEATURES | ANNEALED |
NONDEFINITIVE SPEC/STD DATA | I TYPE AND B VARIETY |
MANUFACTURERS CODE | 96906 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MS36078-2 |
MANUFACTURERS CODE | 81348 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | NNNG00475 |
Restrictions/Controls & Freight Information | NSN 6640-00-299-8690
Category | Code | Description |
---|---|---|
Shelf-Life Code: | Z | 240 months |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 6640-00-299-8690
Category | Code | Description |
---|---|---|
Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | Z | 240 months |
Purchasing | QTY UOM |
6 EA : Each |