NSN 6640-00-264-0655 20301000, 20301-000, 00-264-0655
Product Details | LABORATORY CENTRIFUGE
6640-00-264-0655 A mechanical device using centrifugal force to separate liquids from solids, which might normally be held by them in suspension, or a liquid of one density from that of another.
Part Alternates: 20301000, 20301-000, 6640-00-264-0655, 00-264-0655, 6640002640655, 002640655
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 18 JUL 1973 | 00-264-0655 | 17093 ( CENTRIFUGE, LABORATORY ) |
Cross Reference | NSN 6640-00-264-0655
Part Number | Cage Code | Manufacturer |
---|---|---|
20301-000 | 08455 | UNIVAR CORP VAN WATERS AND ROGERS INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-00-264-0655
Related Products | NSN 6640-00-264-0655
Technical Data | NSN 6640-00-264-0655
Characteristic | Specifications |
---|---|
SEPARATION UNIT TYPE | CONICAL |
HEAD PLACE QUANTITY | 8 |
PLACE CONTAINER SIZE | 50.0 CUBIC CENTIMETER TUBE |
SAFETY CAP | NOT INCLUDED |
MAXIMUM SPEED RATING IN RPM | 8300.0 |
OPERATION METHOD | ELECTRIC |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 115.0 |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | SINGLE |
GUARD BOWL | INCLUDED |
INSIDE DIAMETER | 16.500 INCHES NOMINAL |
DEPTH | 17.000 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 6640-00-264-0655
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |