Technical Data | NSN 6640-00-110-8959

Characteristic Specifications
OPERATING TEMP RANGE IN DEG CELSIUS 35.0 TO 343.0
HEAT SOURCE FOR WHICH DESIGNED INTEGRAL
HEATING METHOD ELECTRICAL
CURRENT TYPE AC
VOLTAGE RATING 240.000 VOLTS NOMINAL
FREQUENCY RATING 60.0 HERTZ NOMINAL
PHASE SINGLE
POWER RATING 4.0 KILOWATTS NOMINAL
CIRCULATION METHOD FORCED AIR
WATER JACKET NOT PROVIDED
OVERALL HEIGHT 49.000 INCHES NOMINAL
OVERALL WIDTH 40.000 INCHES NOMINAL
OVERALL DEPTH 32.000 INCHES NOMINAL
INSIDE HEIGHT 20.000 INCHES NOMINAL
INSIDE WIDTH 25.000 INCHES NOMINAL
INSIDE DEPTH 20.000 INCHES NOMINAL
INSULATED CABINET PROVIDED
CABINET OUTER WALL MATERIAL STEEL
CABINET INNER WALL MATERIAL STEEL, STAINLESS
CABINET MOUNTING TYPE STAND
OUTER DOOR QUANTITY 1
OUTER DOOR MATERIAL STEEL
OUTER DOOR INSULATION FEATURE INCLUDED
SHELF QUANTITY 2
SHELF ADJUSTABILITY ADJUSTABLE
SHELF MATERIAL STEEL
MATERIAL CHARACTERISTIC EXPANDED
VACUUM CHAMBER NOT INCLUDED
ACCESSORY COMPONENTS AND QUANTITY THERMOMETER 1! TERMINAL BOX 1
CONTROL TYPE OVER-TEMPERATURE

Restrictions/Controls & Freight Information | NSN 6640-00-110-8959

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 014500 APPARATUS CHEMICAL LABORATORY
Less than car load rating
Less than truck load rating F 150.0
Water commodity Code 652 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity V Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6640-00-110-8959

Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each