NSN 6630-01-456-7152 ACH-5, 980250, 98-0250
Product Details | HYDROCHLORIC ACID PRESCORED AMPULE
6630-01-456-7152
Part Alternates: ACH-5, 980250, 98-0250, ACH5, 6630-01-456-7152, 01-456-7152, 6630014567152, 014567152
Instruments and Laboratory Equipment | Chemical Analysis Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 24-JUN-98 | 01-456-7152 | 77777 ( ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6630-01-456-7152
Related Products | NSN 6630-01-456-7152
Technical Data | NSN 6630-01-456-7152
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | 5 ML; 37% CONCENTRATION; PRESCORED AMPULES CONTAIN HYDROCHLORIC ACID CHEMICAL SOLUTIONS, FOR THE PRESERVATION OF ENVIRONMENTAL SAMPLES; UNIT ISSUE PG OF 24 |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | PRESCORED AMPULE HY 5ML 37%ML CONCENTRATION 24S |
Restrictions/Controls & Freight Information | NSN 6630-01-456-7152
Category | Code | Description |
---|---|---|
Shelf-Life Code: | H | 12 months |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |