NSN 6630-01-332-7885 900978P, 90-0978P, 931046IRR
Product Details | BLOOD GAS ANALYZER
6630-01-332-7885 An instrument designed for determination of the carbon dioxide combining power, oxygen, carbon monoxide and nitrogen of whole blood or blood plasma. May also be used for micro determinations of gas other than blood gases, developed from solutions, such as organic nitrogen and carbon, urea, amino nitrogen, iodates, sulphates, sugar, calcium lactic acid, potassium, and analysis of gas mixtures.
Part Alternates: 900978P, 90-0978P, 931046IRR, 6630-01-332-7885, 01-332-7885, 6630013327885, 013327885
Instruments and Laboratory Equipment | Chemical Analysis Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 17 JAN 1991 | 01-332-7885 | 38049 ( ANALYZER, BLOOD GAS ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6630-01-332-7885
Related Products | NSN 6630-01-332-7885
Technical Data | NSN 6630-01-332-7885
Characteristic | Specifications |
---|---|
METHOD OF ANALYSIS | POLAROGRAPHIC AND POTENTIOMETRIC/ION SELECTIVE ELECTRODE |
TEST TYPE FOR WHICH DESIGNED | BLOOD GASES AND ELECTROLYTES; HCO3; HCT; BASE EXCESS AND O2 SAT |
ANALYSIS TEST/MEASUREMENT RANGE | PO2 0-600 MMHG; PH 6.8 TO 7.8; PCO2 8 TO 99 MMHG; K 0.1 TO 9.9 MM/L; NA 100 TO 200 MM/L; CA 0.25 TO 4.25 MM/L; HCT 10 TO 75 PCT; HCO3 3.0 TO 60 MM/L; TCO2 3.0 TO 60 MM/L; BASE EXCESS -30 TO +30 MM/L; O2 SAT 30 TO 99 PCT |
TEST SAMPLE/SPECIMEN SIZE | 0.5 ML |
TEST SAMPLE/SPECIMEN TYPE | WHOLE BLOOD |
FEATURES PROVIDED | DIGITAL DISPLAY SCREEN AND INTEGRAL PRINTER AND SELF-CALIBRATION |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 120.0 AND 230.0 |
FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL |
HEIGHT | 8.400 INCHES |
WIDTH | 9.100 INCHES |
DEPTH | 18.300 INCHES |
UNIT OF ISSUE WEIGHT | 27.00 POUNDS |
UNIT OF ISSUE CUBE | 1.00 CUBIC FEET |
SPECIAL FEATURES | UTILIZES A DISPOSABLE CARTRIDGE/TEST PACK THAT CONTAINS ALL ELECTRODES, CALIBRATING AND FLUSH SOLUTIONS AND GASES PLUS A WASTE CONTAINER FOR PROCESSED BLOOD, CALIBRATING, AND QC SOLUTIONS. THE CARTRIDGE/TEST PACK SHALL ELIMINATE THE NEED FOR GAS TANKS, EXTERNAL SOLUTIONS, AND ELECTRODE MAINTENANCE. SHALL BE PRE-PROGRAMED TO AUTOMATICALLY PERFORM TWO-POINT CALIBRATION EVERY HOUR AND ONE-POINT CALIBRATION EVERY 90 SECONDS. CAPABLE OF AUTOMATIC ASPIRATION OF THE SAMPLE,AND TO PROCESS, DISPLAY, AND PRINT THE RESULTS IN LESS THAN 2 MINUTES. SHALL BE SUITABLE FOR THE FIELD ENVIRONMENT. |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | BLOOD GAS ANALYZER 120/230V 50/60 HZ AC: |
Restrictions/Controls & Freight Information | NSN 6630-01-332-7885
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 056680 | DENTAL/MEDICAL/SURG INST R MACHINE |
Less than car load rating | ||
Less than truck load rating | F | 150.0 |
Water commodity Code | 651 | unknown |
Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6630-01-332-7885
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | Q | Other Support Equipment |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |