NSN 6630-01-110-4844 GPC AUTOPREP 1002, GPC AUTOPREP 1002A, GPC AUTOPREP 1002B
Product Details | GAS CHROMATOGRAPH
6630-01-110-4844 A device for the chromatographic separation of liquid and/or gaseous mixtures into pure components and for quantitatively estimating the proportion of each component in the original mixture.
Part Alternates: GPC AUTOPREP 1002, GPC AUTOPREP 1002A, GPC AUTOPREP 1002B, GPCAUTOPREP1002, GPCAUTOPREP1002A, GPCAUTOPREP1002B, 663017170000, 6630-1717-0000, 6630-01-110-4844, 01-110-4844, 6630011104844, 011104844
Instruments and Laboratory Equipment | Chemical Analysis Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 01-APR-81 | 01-110-4844 | 61620 ( CHROMATOGRAPH, GAS ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6630-01-110-4844
Related Products | NSN 6630-01-110-4844
Technical Data | NSN 6630-01-110-4844
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | USES PRINCIPLE OF GEL PERMEATION CHROMATOGRAPHY TO SEPARATE MOLECULES SUBSTANCES; CABINET,130 LBS; CONTROLLER UNIT,11 LBS; 22 IN. W,23 IN. D,41 IN.H; FLOW RATE SELECTABLE 0.75-10 ML/MIN. GLASS W/TEFLON FITTINGS; RESIN PCT.3 CROSS LINKED POLYMER; 23 5 ML SAMPLES CONTAINED IN CALIBRATED TEFLON SAMPLE LOOPS,ATTACHED TO 24 PORT ROTARY VALVES; ADJUSTABLE PRESSURE LIMIT SWIITCH AUTOMATICALLY SHUTS UNIT OFF; EXHAUST SYSTEM; SAMPLE INJECT VALVE; TIMING BY INTERNAL CLOCK; BLUE W/WHITE TRIM |
Restrictions/Controls & Freight Information | NSN 6630-01-110-4844
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |