NSN 6630-01-006-6100 0A3502, 0A350-2, 01-006-6100
Product Details | OXYGEN ANALYZER
6630-01-006-6100 An item used for the detection and measurement of the oxygen content in air or other gases.20265150057Medical and Surgical Instruments, Equipment, and Supplies66300029Chemical Analysis Instruments
Part Alternates: 0A3502, 0A350-2, 6630-01-006-6100, 01-006-6100, 6630010066100, 010066100
Instruments and Laboratory Equipment | Chemical Analysis Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 19 JUL 1975 | 01-006-6100 | 27944 ( ANALYZER, OXYGEN ) |
Cross Reference | NSN 6630-01-006-6100
Part Number | Cage Code | Manufacturer |
---|---|---|
0A350-2 | 51317 | MELOY LABORATORIES INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6630-01-006-6100
Related Products | NSN 6630-01-006-6100
Technical Data | NSN 6630-01-006-6100
Characteristic | Specifications |
---|---|
DETECTION RANGE IN PERCENT | 0.0 TO 100.0 |
CARRYING HANDLE | NOT INCLUDED |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 115.0 |
FREQUENCY IN HERTZ | 50.0 OR 60.0 |
PHASE | SINGLE |
ANALYSIS CELL TYPE | RAPID RESPONSE |
CORROSION RESISTANT FEATURE | INCLUDED |
SAMPLE TYPE | FLOWING |
RESPONSE TIME | 15.0 SECONDS |
OVERALL WIDTH | 19.000 INCHES NOMINAL |
OVERALL DEPTH | 20.000 INCHES NOMINAL |
OVERALL HEIGHT | 12.000 INCHES NOMINAL |
SPECIAL FEATURES | RANGES: 0 TO .01 PPM,0 TO .1 PPM,0 TO .5 PPM,0 TO 1 PPM,0 TO 5 PPM,0 TO 10 PPM; MIN DETECTABLE SENSITIVITY .0005 PPM; RELATIVE HUMIDITY RANGE 10 TO 95 PCT.; PRECISION PORM 2 PCT.; OPERATIONAL PERIOD 7 DAYS UNATTENDED; AMBIENT TEMP RANGE 10 TO 40 DEG C; MEASURES CONCENTRATION OF OZONE IN AMBIENT AIR BY PHOTOMETRICALLY MONITORING THE CHEMILUMINESCENCE RESULTING FROM THE REACTION OF ETHYLENE GAS WITH OZONE; BUILT-IN CALIBRATION SYSTEM |
MANUFACTURERS CODE | 51317 |
DESIGN CONTROL REFERENCE | 0A350-2 |
Restrictions/Controls & Freight Information | NSN 6630-01-006-6100
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |