NSN 6625-01-594-1431 MCRVACUI0DC, MCR-VAC-UI-0-DC, 01-594-1431
Product Details | SPEC INDICATOR
6625-01-594-1431
Part Alternates: MCRVACUI0DC, MCR-VAC-UI-0-DC, 6625-01-594-1431, 01-594-1431, 6625015941431, 015941431
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 22 APR 2011 | 01-594-1431 | 77777 ( ) |
Cross Reference | NSN 6625-01-594-1431
Part Number | Cage Code | Manufacturer |
---|---|---|
MCR-VAC-UI-0-DC | 5Y407 | PHOENIX CONTACT SERVICES INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-594-1431
Related Products | NSN 6625-01-594-1431
Technical Data | NSN 6625-01-594-1431
Characteristic | Specifications |
---|---|
MATERIAL | PLASTIC NYLON |
OVERALL LENGTH | 114.5 MILLIMETERS NOMINAL |
OVERALL WIDTH | 22.5 MILLIMETERS NOMINAL |
OVERALL HEIGHT | 99.0 MILLIMETERS NOMINAL |
VOLTAGE IN VOLTS AND CURRENT TYPE | 18.5 DC AND |
CURRENT RATING | 30.0 MILLIAMPERES |
COLOR | GREEN |
SPECIAL FEATURES | INPUT VOLTAGE RANGES - 0-370VAC, O-250VAC, 0-170VAC, 0-120VAC, 0-80VAC, 0-54VAC, 0-36VAC AND 0-24VAC; INPUT RESISTANCES - 370 KILOHM, 250 KILOHM, 170, 120 KILOHM, 80 KILOHM, 54 KILOHM, 36 KILOHM AND 24 KILOHM; PLUGGABLE SCREW CONNECTION M3; 45-400HZ MEASURING FREQUENCY RANGE; -25 TO -60 DEG C OPERATING TEMPERATURE; 300VDC INSULATION VOLTAGE |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | MCR VOLTAGE MEASURING TRANSDUCER |
Restrictions/Controls & Freight Information | NSN 6625-01-594-1431
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |