NSN 6625-01-574-6512 EF6091, 01-574-6512, 015746512
Product Details | INTERFERE ELECTRICAL FIELD PROBE
6625-01-574-6512 An item which is specifically designed for use as a search probe in conducting radio interference measurements by determining the existence and extent of an interfering electrical field.
Part Alternates: EF6091, 6625-01-574-6512, 01-574-6512, 6625015746512, 015746512
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 04 JUN 2009 | 01-574-6512 | 20968 ( PROBE, ELECTRICAL FIELD, INTERFERENCE MEASURING ) |
Cross Reference | NSN 6625-01-574-6512
Part Number | Cage Code | Manufacturer |
---|---|---|
EF6091 | 99899 | L-3 COMMUNICATIONS CORPORATION DBA NARDA MICROWAVE EAST |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-574-6512
Related Products | NSN 6625-01-574-6512
Technical Data | NSN 6625-01-574-6512
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 318.0 MILLIMETERS NOMINAL |
END ITEM IDENTIFICATION | NBM-500 SERIES METERS |
OVERALL DIAMETER | 66.0 MILLIMETERS NOMINAL |
SPECIAL FEATURES | PROBE CONTAINS THREE ORTHOGONALLY ARRANGED DIPOLES WITH DETECTOR DIODES; DIODE VOLTAGES, LINEARIZED INTERNALLY EACH CORRESPOND TO RMS VALUE OF SPATIAL COMPONENTS; ISOTROPIC MEASUREMENT RESULT IS OBTAINED BY ADDITION WITHIN THE PROBE; DETECTS ELECTRIC FIELDS FROM 100 MHZ TO 60 GHZ |
PART NAME ASSIGNED BY CONTROLLING AGENCY | E-FIELD PROBE |
Restrictions/Controls & Freight Information | NSN 6625-01-574-6512
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |