Product Details | AMMETER

6625-01-547-1768 An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see GALVANOMETER.

Part Alternates: ACA20PC3AC1RL, ACA-20PC-3-AC1-RL, 3744602, 374-4602, 6625-01-547-1768, 01-547-1768, 6625015471768, 015471768

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 12 JAN 2007 01-547-1768

Cross Reference | NSN 6625-01-547-1768

Part Number Cage Code Manufacturer
374-4602 K2504 RS COMPONENTS LIMITED
ACA-20PC-3-AC1-RL 50721 MURATA POWER SOLUTIONS, INC. DIV MURATA POWER SOLUTIONS / DATEL
ACA-20PC-3-AC1-RL K2604 C & D TECHNOLOGIES NCL LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-547-1768

Technical Data | NSN 6625-01-547-1768

Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIGITAL DISPLAY
DISPLAY TYPE LIGHT EMITTING DIODE
DISPLAY DIGIT QUANTITY 4
MEASUREMENT RANGE 0.0 TO 50.0 AMPERES SINGLE INDICATOR SINGLE RANGE
ACCURACY RATING PORM O.15 PCT FS PORM 6 COUNTS SINGLE INDICATOR SINGLE RANGE
DISPLAY COLOR RED SINGLE INDICATOR SINGLE RANGE
BACKGROUND COLOR BLACK SINGLE INDICATOR SINGLE RANGE
CIRCUIT CURRENT FOR WHICH DESIGNED AC
OPERATING VOLTAGE RATING IN VOLTS 85.0 AC MINIMUM AND 264.0 AC MAXIMUM
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 1 BRACKET
SPECIAL FEATURES BUILT-IN CURRENT TRANSFORMER

Restrictions/Controls & Freight Information | NSN 6625-01-547-1768

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information