Product Details | RESISTANCE STANDARD

6625-01-544-5604 An item whose resistance is known to a high degree of accuracy which permits it to be used as a basis for determining the value of other resistances, capacitances, and/or inductances and for calibrating instruments. See also RESISTOR, FIXED (as modified) and SHUNT, INSTRUMENT. Excludes RESISTOR, DECADE.

Part Alternates: SRL100K, SRL-100K, 6625-01-544-5604, 01-544-5604, 6625015445604, 015445604

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 16 OCT 2006 01-544-5604

Cross Reference | NSN 6625-01-544-5604

Part Number Cage Code Manufacturer
SRL-100K 62015 IET LABS., INC. DBA IET LABS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-544-5604

Technical Data | NSN 6625-01-544-5604

Characteristic Specifications
OVERALL DIAMETER 4.150 INCHES NOMINAL
OVERALL WIDTH 5.000 INCHES NOMINAL
OVERALL HEIGHT 3.400 INCHES NOMINAL
SPECIAL FEATURES FOUR WIRE KELVIN MEASUREMENTS;LOWPOWER;18 TO 28 DEGREES CELESUS TEMPERATURE RANGE;0 TO 40 DEGREES CELESUS STORAGE TEMPERATURE;WEIGHS 0.73KG;1MA MAXIMUM CURRENT;100 VOLT MAXIMUM VOLTAGE
III END ITEM IDENTIFICATION TEST SET EQUIPMENT
III UNPACKAGED UNIT WEIGHT 1.600 POUNDS
III TYPE/MODEL DESIGNATION SRL-100K
III PART NAME ASSIGNED BY CONTROLLING AGENCY HIGH ACCURACY STANDARD RESISTANCE

Restrictions/Controls & Freight Information | NSN 6625-01-544-5604

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information