NSN 6625-01-536-8513 DTX 1800MS, DTX1800MS, 01-536-8513
Product Details | ELECTRICAL CABLE TEST SET
6625-01-536-8513 A test set primarily designed for use in making examinations of electrical cables. Can be used for locating shorts, crosses, and grounds in electrical cables. This would also permit locating high resistant faults. See also TEST SET (1), POWER-SPECIAL PURPOSE ELECTRICAL CABLE ASSEMBLY. Excludes REFLECTOMETER, METALLIC TIME DOMAIN.
Part Alternates: DTX 1800MS, DTX1800MS, 6625-01-536-8513, 01-536-8513, 6625015368513, 015368513
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 18 JAN 2006 | 01-536-8513 | 03633 ( TEST SET, ELECTRICAL CABLE ) |
Cross Reference | NSN 6625-01-536-8513
Part Number | Cage Code | Manufacturer |
---|---|---|
DTX 1800MS | 89536 | FLUKE CORPORATION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-536-8513
Related Products | NSN 6625-01-536-8513
Technical Data | NSN 6625-01-536-8513
Characteristic | Specifications |
---|---|
TEST TYPE FOR WHICH DESIGNED | CABLE AUTOTEST |
OPERATING TEST CAPABILITY | TONE GENERATOR 440/831 HZ |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AC VOLTAGE RATING | 108.0 VOLTS MINIMUM AND 132.0 VOLTS MAXIMUM |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
DC VOLTAGE RATING | 15.0 VOLTS NOMINAL |
INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
HEIGHT | 2.400 INCHES NOMINAL |
LENGTH | 8.500 INCHES NOMINAL |
WIDTH | 4.400 INCHES NOMINAL |
SPECIAL FEATURES | DTX CABLE ANALYZER; 3.7 IN LCD BACKLIT DISPLAY; OP TEMP 0 TO 45 DEG C |
Restrictions/Controls & Freight Information | NSN 6625-01-536-8513
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |